Low Energy Operation; Guidelines For Recommended Pump Operating Hours - Davey SilensorPRO SP200BT Installation And Operating Instructions Manual

50/60hz
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Low energy operation

Your SilensorPRO SP200BT has speed settings from 1,500 - 3,600rpm. The SilensorPRO SP400BT has
speed settings from 1,050 - 3,100rpm. Speed 1 being the slowest and speed 10 being the fastest.
• Speed 1 provides the lowest speed and therefore the greatest energy efficiency and savings.
Operation
Backwashing your media filter
Pool Filtration
Suction pool cleaner operation
Manually cleaning your pool
Water Feature operation
Spa Jet operation
In-floor cleaning systems
Solar pool heating

Guidelines for recommended pump operating hours

Typical residential pool turnover rate shall be a single turnover of the full volume of the pool water, within the
daily period that the pump would normally be operating. The table below provides a guide only to the running
times of your pump while in filtration mode in order to achieve the minimum turnover rate:
SilensorPRO SP200BT
Pool size
(Litres)
20,000
30,000
40,000
50,000
60,000
80,000
100,000
SilensorPRO SP400BT
Pool size
(Litres)
20,000
30,000
40,000
50,000
60,000
80,000
100,000
Speed Setting (hours)
Speed 1
3.3
5.0
6.7
8.3
10.0
13.3
16.7
Speed Setting (hours)
Speed 1
2.4
3.7
4.9
6.1
7.4
9.8
12.3
8
Recommended Speed Setting
Backwash Speed
Speed 1 to 4
Speed 5 to 8
Speed 9 to 10
Speed 5
1.7
2.5
3.3
4.2
5.0
6.7
8.3
Speed 5
1.3
2.0
2.7
3.3
4.0
5.3
6.7
Speed 10
1.1
1.7
2.2
2.8
3.3
4.4
5.6
Speed 10
0.9
1.4
1.9
2.3
2.8
3.8
4.7
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silensorpro sp400bt

Table of Contents