Setup (continued)
Group
PNU
Parameter
Regfrigerant
2551
o30
2548
RF1
2549
RF2
2550
RF3
113
r09
Sensors
2033
o21
2034
o20
System
50020
-
50021
-
50051
-
64200
LBO
64100
HWM
64309
-
Service
2046
RAL
Alarm
20001
-
20002
-
20005
-
20006
-
50006
-
Readout
2531
u16
2535
u22
2536
u21
2537
u20
2542
u24
2543
u25
2544
u26
3101
-
3102
-
50033
-
64306
-
14
Superheat Controller EIM 336
Symbolic name
Min.
Refrigerant
0
Rfg. fac. A1
8000
12000
Rfg. fac. A2
-4000
-1000
Rfg. fac. A3
1000
Adjust S2
-10
Max. transducer
1
pressure
Min. transducer
0
pressure
Avg KT0 time
10
Avg OD 3 hours
0
Sampling time
1
Limited list
0
HW main switch
0
Manual OD as
0
steps
Reset alarm
0
EKC Error
0
S2 Error
0
Pe inp.error
0
No Rfg. Sel.
0
LOC Alarm
0
S4 air temp
-200
Superheat Ref
0
Superheat
0
S2 Temp
-200
opening %
0
Evap Press P
-200
e
Evap Temp T
-200
e
Closed valve T
0
LOC Tmr
0
Avg opening
0
SWVer shdw
x
DKRCC.PS.RQ0.B5.02 / 520H8256
Max.
Default
Units
e2
31
23
ü
10428
ü
-2255
ü
3000
2557
ü
0
0
K
ü
bar
200
16
(abs.) ü
bar
1
0
(abs.) ü
3600
180
ü
per
1000
100
ü
mill
10
1
sec.
ü
1
0
ü
1
0
ü
1
0
ü
1
0
1
0
1
0
1
0
1
0
1
0
200
0
°C
100
0
K
100
0
K
200
0
°C
100
0
%
bar
200
0
(abs.)
200
0
°C
2000
0
2000
0
100
0
%
x
x
W
*10
Description
1 = R12
14 = R32
2 = R22
15 = R227
3 = R134a
16 = R401A
4 = R502
17 = R507
5 = R717
18 = R402A
6 = R13
19 = R404A
7 = R13b1
20 = R407C
ü
8 = R23
21 = R407A
9 = R500
22 = R407B
10 = R503
23 = R410A
11 = R114
24 = R170
12 = R142b
25 = R290
13 = User
26 = R600
defined
27 = R600a
Adiabatic constant A1
ü
Adiabatic constant A2
ü
ü
Adiabatic constant A3
S2 Offset adjustment to correct the
ü
ü
sensor signal due to long wires etc.
Maximum transducer pressure (in bar
ü
ü
absolute * 10)
Minimum transducer pressure (in bar
ü
ü
absolute * 10)
Average time for KT0 used as filtervalue
for the average opening degree calcula-
ü
tion when calculating the KT0
Average OD, updated every 3 hours
ü
ü
Algorithm sampling time
ü
Modbus translation table for limited list
ü
of sequential registers
1 = S4 input is HW Main Switch
ü
Enable the manual OD in o45 to be
entered as halfsteps. Readouts are still in
ü
percent
1 = clear alarm
ü
Common error flag. EKC Error is SET if any
other Error Alarm is ON.
S2 sensor error. If the sensor error
occurs, the valve OD will be set to 80%
of the Avg. opening (PNU 50021) - see
troubleshooting.
AKS 32R out of range. If the sensor error
occurs, the valve OD will be set to 80%
of the Avg. opening (PNU 50021) - see
troubleshooting.
Refrigerant not selected
Loss of charge alarm. No action will be
performed except setting the alarm.
S4 temperature in °C measured with PT
ü
1000 sensor connected to KM2
Current superheat reference
ü
Current superheat (S2 - evaporator
ü
temperature)
S2 temperature in °C measured with a PT
ü
1000 sensor connected to KM1.
Actual opening degree
Evaporator pressure measured with
ü
ratiometric pressure transmitter at KM6.
Evaporator temperature (converted from
ü
evaporator pressure)
Closed valve timer
Loss Of Charge time
Average opening degree. If it has never
run before it will give the value of PNU
50021 at start up.
Copy of 2003. This displays the version
number in a non-EKC format. For
example 123 means vers 1.23
© Danfoss A/S (AC-MCI / sw), 2014-11
28 = R744
29 = R1270
30 = R417A
31 = R422A
32=R413A
33=R422D
34=427A
35=R438A
36=Opteon
XP10
37 =R407F