CENTRIFUGAL PUMPS 60Hz SPECIFICATION Rev. E PUMP Type of liquid Clean water min. -5 Liquid max. +60 (CDX 70/076-70/106-70/156) Handled Temperature [°C] max. +90 max. +110 (H-HS-HW-HSW) max. +120 (E) Maximum working pressure [MPa] Impeller Closed centrifugal type Construction Shaft seal type...
In order to avoid the risk of over-heating, the pumps should not be used at a flow rate below 10% of best efficiency point. Symbols explanation: Q = volume flow rate H = total head = pump power input (shaft power) = pump efficiency NPSH = net positive suction head required by the pump EBARA PUMPS EUROPE S.p.A.
Page 6
60Hz PERFORMANCE CURVE Rev. E CDX 70/076 (0.55 kW) - Impeller diameter = 115 mm CDX 70/106 (0.75 kW) - Impeller diameter = 132 mm CDX 70/156 (1.1 kW) - Impeller diameter = 157 mm Rotation speed ≈ 3450 min Test standard: ISO 9906 –...
Page 7
CDX 120/106 (0.75 kW) - Impeller diameter = 115 mm CDX 120/156 (1.1 kW) - Impeller diameter = 132 mm CDX 120/206 (1.5 kW) - Impeller diameter = 157 mm Rotation speed ≈ 3450 min Test standard: ISO 9906 – Annex A EBARA PUMPS EUROPE S.p.A.
Page 8
CDX 200/156 (1.1 kW) - Impeller diameter = 115 mm CDX 200/206 (1.5 kW) - Impeller diameter = 132 mm CDX 200/306 (2.2 kW) - Impeller diameter = 144 mm Rotation speed ≈ 3450 min Test standard: ISO 9906 – Annex A EBARA PUMPS EUROPE S.p.A.
Special version, see page 301 NBR for CDX 70/076-70/106-70/156 FPM for CDX H-HS-HW-HSW of the CDX 70/076-70/106-70/156 Whit gasket in NBR only for version single phase CDXM 70/076, 70/106, 70/156, 120/106, 120/156, 200/156 Only for version single phase CDXM 120/206, 200/206 Only for “L”...
100% 100% Phase Phase 110-115 V 220-230 V 220 V F] F] 380 V 460 V 110-115 V 220-230 V 220 V 380 V 460 V CDXM 70/076 CDX 70/076 0.55 0.75 12.5 0.70 0.74 28.1 15.0 CDXM 70/106 CDX 70/106 0.75...