TERMINAL CIRCUIT
Fuel pump relay
E61 1
E61-1
(TYPE B only: See NOTE.)
E61-2
E61-3
Cruise control module
E61-4
Tachometer
A / C condenser fan motor relay
E61-5
E61 5
(if equipped)
Cruise control module
E61-6
(Throttle opening signal)
(if equipped)
E61-7
E61 7
"O / D OFF" lamp (A / T VEHICLE)
"O / D OFF" lamp (A / T VEHICLE)
E61 8
E61-8
Main relay
Main relay
Power / Normal change switch
E61 9
E61-9
(A / T VEHICLE)
E61 10
E61-10
"POWER" lamp (A / T VEHICLE)
"POWER" lamp (A / T VEHICLE)
E61-11
E61-12
Fuel level sensor
E61 13
E61-13
Heater blower switch
Heater blower switch
E61-14
E61 14
Overdrive cut switch (A / T VEHICLE)
Overdrive cut switch (A / T VEHICLE)
E61-15
Rear defogger switch (if equipped)
Test switch terminal (vehicle with
E61-16
monitor connector)
Output duty select switch terminal
E61-17
(vehicle with monitor connector)
E61-18
ABS control module (if equipped)
E61-19
CO adjusting resistor (if equipped)
Fuel pump relay
E61-20
E61-20
(TYPE A only: See NOTE.)
NORMAL VOLTAGE
y
———
y
Indicator deflection
between 0 – 1 V
and 10 – 14 V
g
———
(Full) (Empty)
ENGINE GENERAL INFORMATION AND DIAGNOSIS (H25 ENGINE) 6-1-7
For 3 sec. after ignition switch ON or while engine
0 – 2.5 V
running.
After 3 sec. from ignition switch ON with engine
10 – 14 V
stopped.
———
10 – 14 V
Ignition switch ON.
0 – 0.8 V
Ignition switch ON, engine stops.
10 – 14 V
Ignition switch ON.
0 – 2.5 V
A / C condenser fan motor ON.
Ignition switch ON.
For 4 sec. after ignition switch ON, overdrive cut
0 – 2.5 V
switch ON.
After 4 sec. from ignition switch ON and overdrive cut
10 – 14 V
switch OFF.
10 – 14 V
Ignition switch OFF.
0 – 2 V
Ignition switch ON.
For 4 sec. after ignition switch ON, P / N change switch
0 – 1 V
in POWER mode
Ignition switch ON, P / N change switch: NORMAL
10 – 14 V
mode
Ignition switch ON, P / N change switch: POWER
0 – 2.5 V
mode
Ignition switch ON, P / N change switch: NORMAL
10 – 14 V
mode
———
0.7 – 5.5 V
Ignition switch ON.
10 – 14 V
Ignition switch ON, heater blower switch OFF.
0 – 2.5 V
Ignition switch ON, heater blower switch ON.
10 – 14 V
Ignition switch ON, overdrive cut switch OFF.
0 – 1 V
Ignition switch ON, overdrive cut switch ON.
0 – 1 V
Rear defogger switch OFF.
Ignition switch ON.
10 – 14 V
Rear defogger switch ON.
10 – 14 V
Ignition switch ON.
10 – 14 V
Ignition switch ON.
10 – 14 V
Ignition switch ON.
———
For 3 sec. after ignition switch ON or while engine
0 – 2.5 V
running.
After 3 sec. from ignition switch ON with engine
10 – 14 V
stopped.
CONDITION
———
———
———

Advertisement