Emerson Penberthy N2 Series Installation, Operation And Maintenance Instructions
Emerson Penberthy N2 Series Installation, Operation And Maintenance Instructions

Emerson Penberthy N2 Series Installation, Operation And Maintenance Instructions

Tubular gagecocks

Advertisement

Quick Links

Penberthy SerieS N2/K2 Tubular gagecocKS
InstallatIon, operatIon and maIntenance InstructIons
before installation these instructions must be read fully and understood

table OF COntents

Product warranty ................................................ 1
1
about the manual..................................... 2
2
Introduction ............................................. 2
2.1 System description ...................................... 2
3
available models ..................................... 3
temperatures ............................................... 3
3.2 Steam application ........................................ 3
4
Inspection ................................................ 4
4.1 user rating inspection ................................. 4
5
Installation ............................................... 4
5.1 Mounting ....................................................... 4
5.2 Tubular glass installation ............................ 4
5.3 guard rod installation .................................. 4
6
Operation ................................................. 5
6.1 Hydrostatic test ............................................ 5
7
Maintenance ............................................ 5
7.1 Preventative maintenance ........................... 5
7.2 ball check shut-off ...................................... 5
7.3 Troubleshooting ........................................... 6
8
8.1 Disassembly ................................................. 6
8.2 reassembly .................................................. 7
9
disposal at end of useful life ................... 7
10 telephone assistance .............................. 7
11 exploded parts diagram .......................... 8
Table 1 - Standard features .............................. 3
Table 2 - Design ratings .................................... 3
Table 3 - Tubular glass ratings ........................ 3
Figure 1 - PTFe tape wrapping .......................... 4
Figure 2 - exploded parts diagram ................... 8
Emerson.com/FinalControl

PrOduCt warranty

emerson warrants its Penberthy products
as designed and manufactured to be free
of defects in the material and workmanship
for a period of one year after the date of
installation or eighteen months after the date
of manufacture, whichever is earliest. emerson
will, at its option, replace or repair any products
which fail during the warranty period due to
defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to emerson and obtain written
authorization to return the product. Thereafter,
the product shall be returned to emerson with
freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or otherwise altered outside of the emerson
factory, or if it has been subject to misuse,
neglect or accident.
The responsibility of emerson hereunder is
limited to repairing or replacing the product
at its expense. emerson shall not be liable for
loss, damage or expenses related directly or
indirectly to the installation or use of its products
or from any other cause or for consequential
damages. it is expressly understood that
emerson is not responsible for damage or injury
caused to other products, buildings, personnel
or property, by reason of the installation or use
of its products.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of emerson unless made in
writing and signed by the company's general
manager or director of engineering.
© 2017 Emerson. All rights reserved.
VCIOM-04034-en 18/03

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Penberthy N2 Series

  • Page 1: Table Of Contents

    5.2 Tubular glass installation ......4 limited to repairing or replacing the product 5.3 guard rod installation ........4 at its expense. emerson shall not be liable for Operation ..........5 loss, damage or expenses related directly or 6.1 Hydrostatic test ..........5 indirectly to the installation or use of its products Maintenance ..........
  • Page 2: About The Manual

    - a pressure retaining structure through emerson does not have any control over the which fluid passes to enter a tubular glass or manner in which its gagecocks are handled, other apparatus. Provides a rigid, union, or installed or used.
  • Page 3: Available Models

    Penberthy SerieS N2/K2 Tubular gagecocKS InstallatIon, operatIon and maIntenance InstructIons 3 aVaIlable MOdels 3.1 design ratings at maximum and minimum operating temperatures (see table 2) Tubular gagecock standard features are listed in To determine the maximum allowable working the table below: pressure for a specific temperature within the design limits stated below, the user must table 1...
  • Page 4: Inspection

    Penberthy SerieS N2/K2 Tubular gagecocKS InstallatIon, operatIon and maIntenance InstructIons 4 InsPeCtIOn 5.1 Mounting 1. Prior to installation, turn the handwheel or PTFe tape on receipt of a gagecock set, check all lever of each gagecock clockwise until the Direction of wrap components carefully for damage incurred in stem closes against the seat.
  • Page 5: Operation

    Penberthy SerieS N2/K2 Tubular gagecocKS InstallatIon, operatIon and maIntenance InstructIons 6 OPeratIOn 7.1 Preventative maintenance Visibly inspect ball check and ball seats in the on all installations the following items should gagecock body. remove any foreign matter and/ before initializing gagecock operation, check be evaluated regularly by the user for purposes or replace with new ball checks if inspection that all installation procedures have been...
  • Page 6: Troubleshooting

    Penberthy SerieS N2/K2 Tubular gagecocKS InstallatIon, operatIon and maIntenance InstructIons 7.3 troubleshooting 8 reMOVal - dIsasseMbly - reasseMbly stem packing leakage - can often be warnInG stopped by tightening the stem packing nut. if leak persists, the stem packing should be Use only qualified, experienced personnel who replaced by following steps 1) through 4) are familiar with tubular gagecock equipment...
  • Page 7: Reassembly

    You must obtain a return authorization positive stop. (r.a.) number from emerson before returning 13. Tighten vessel coupling nut (13) on upper anything. Failure to do so will result in the unit gagecock.
  • Page 8: Exploded Parts Diagram

    Penberthy is a mark owned by one of the companies in the emerson automation Solutions business unit of emerson electric co. emerson automation Solutions, emerson and the emerson logo are trademarks and service marks of emerson electric co.

This manual is also suitable for:

Penberthy k2 seriesPenberthy n2aPenberthy k2aPenberthy n2cPenberthy n2bPenberthy k2b ... Show all

Table of Contents