Getting Started and Product Document of Compliance for the Cisco IR1101 Industrial Integrated Services Router
Warning: Explosion Hazard - The area must be known to be nonhazardous before installing, servicing, or replacing
the unit. Statement 1082
Warning:
In order to comply with FCC radio frequency (RF) exposure limits, antennas for this product should be
located a minimum of 11.8 in. (30 cm) or more from the body of all persons. Statement 332
Warning:
Read the installation instructions before connecting the system to the power source. Statement 1004
Warning:
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: 60Vdc minimum, 5A maximum. Statement 1005
Warning:
This unit is intended for installation in restricted access areas. A restricted access area can be accessed
only through the use of a special tool, lock and key, or other means of security. Statement 1017
Warning:
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an
electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning:
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning:
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning:
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of 140°F (60°C) Statement 1047
Warning:
Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature outside
the enclosure. Statement 1067
Warning:
Installation of the equipment must comply with local and national electric codes. Statement 1074
Warning:
Avoid using or servicing any equipment that has outdoor connections during an electrical storm. There
may be a risk of electric shock from lightning. Statement 1088
Warning:
The product is to be connected to a IEC 60950 compliant limited power source (LPS). Statement 170
Caution:
The equipment shall only be used in an area of not more than pollution degree 2, as defined in IEC 60664-1.
The equipment shall be installed in a certified enclosure that provides a degree of protection not less than IP 54 in
accordance with IEC 60079-15.
Caution:
When installed in a minimum IP54 certified enclosure, the product must be made accessible by tool only.
Caution:
Airflow around the Router must be unrestricted. The dimensions (height x width x depth) are 13.3(h) x 12.5(d)
x 5.8(w) cm (5.22" x 4.92" x 2.27). To prevent the Router from overheating, there must be a minimum of 1.0 in. (25.4
mm) around all surfaces of the Router.
Contact your Cisco Technical Assistance Centre (TAC) if tighter spacings are required.
Caution:
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D, or only nonhazardous locations.
NOTE:
Marked DC Input ratings: 12-48Vdc, 2.8A.
NOTE:
This product is suitable for use in environmental air space in accordance with section 300.22.C of the National
Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should
not install the power supply or power injector in air handling spaces.
NOTE:
The maximum ambient operating temperature range is –40 to 140°F (–40 to 60°C).