Harmar Mobility HELIX Installation & Service Manual page 12

Curved stair lift
Hide thumbs Also See for HELIX:
Table of Contents

Advertisement

INSTALLATION
16. Controls
17. Tones with red status light on
Tones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Beeps
Runaway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
12V Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Conflicting Switches Footrest . . . . . . . . . . . . . . . . . . . . .3
UP & Footrest DOWN
Conflicting Switches Obstruction . . . . . . . . . . . . . . . . .4
UP & Obstruction Down . . . . . . . . . . . . . . . . . . . . . . . . . .5
Conflicting Switches Footrest . . . . . . . . . . . . . . . . . . . . .6
UP & Obstruction DOWN
Conflicting Switches STOP UP & STOP . . . . . . . . . . . . .7
DOWN switches both Detected
Conflicting Switches STOP UP & STOP . . . . . . . . . . . . .8
DOWN switches both not Detected
Helix Only LIMIT Switch Dectected . . . . . . . . . . . . . . . .9
12
Controls
Emergency Safety
Key Lock (Optional)
Power Switch
Status Light
(Red = Major Fault, Yellow = Obstruction, Green = Ready)
Power On Light
Charging Light
Test/Diagnostic Port
This port enables you to connect a PC to the unit to check
several functions on the unit.
| www.harmar.com | 800-833-0478
© 2018 Harmar Mobility, LLC • All Rights Reserved