rollease acmeda AUTOMATE ARC Manual

Venetian blind tilt motor

Advertisement

Quick Links

AUTOMATE
ARC
433 MHZ
BI-DIRECTIONAL
AUTOMATE
| ARC™ Venetian blind motor enables motorized tilting function of most 2"
venetian blinds. Precisely control the openness of blind vanes or simply recall a favorite
position.
FEATURES:
• Electronic Limits
• 433 MHz Bi-Directional RF Communication
• Favorite Position
• 3 x Selectable Rpm
• Jog or latch & Run Modes
| VT 1.0
VENETIAN BLIND TILT MOTOR
ELECTRONIC
LIMIT
FAVORITE
LEVELLING
POSITION
CONTROL
SELECTABLE
RPM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUTOMATE ARC and is the answer not in the manual?

Questions and answers

Summary of Contents for rollease acmeda AUTOMATE ARC

  • Page 1 AUTOMATE ™ | VT 1.0 VENETIAN BLIND TILT MOTOR ™ 433 MHZ ELECTRONIC FAVORITE LEVELLING SELECTABLE BI-DIRECTIONAL LIMIT POSITION CONTROL AUTOMATE | ARC™ Venetian blind motor enables motorized tilting function of most 2” ™ venetian blinds. Precisely control the openness of blind vanes or simply recall a favorite position.
  • Page 2 NOTES 2 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 3: Table Of Contents

    6.2 Using a pre-existing controller FAVORITE POSITIONING 7.1 Set favorite position 7.2 Send shade to favorite position 7.3 Delete favorite position SLEEP MODE 8.1 Enter sleep mode 8.2 Exit sleep mode TROUBLESHOOTING 3 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 4 Keep antenna straight and clear from metal objects • Do not cut the antenna. • Use only Rollease Acmeda hardware. • Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation. • Ensure torque and operating time is compatible with end application.
  • Page 5: Assembly

    Step 3. Remove motor, mark and drill hole where P1 button can be accessed. Step 4. Reinstall motor, ensuring power cord and Antenna extend freely from the headrail cap. 5 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 6: Wiring

    Automate DC motors are powered from a 12V DC power source. AA Battery wands, re-chargeable battery packs and A/C power supplies are available, with a variety of quick connect extension cords. For centralized installations, power supply range can be extended with 18/2 wire (not available through Rollease Acmeda). •...
  • Page 7: P1 Button Functions

    Hold P1 Approx Motor Response RELEASE P1 Sleep Mode Approx Motor Response RELEASE P1 Reverse Direction Approx. Motor Response Reset To Factory RELEASE P1 Settings Approx. Motor Response 7 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 8: Intial Set-Up

    DOWN until motor responds Motor Reponse Reversing motor direction using this method is only possible during initial set-up, prior to first time limit setting, or after a re-set of motor 8 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 9: Set Limits

    To save lower limit, hold DOWN and STOP. Quick Press = Step Long Press = Continuous Travel Motor Response Approx. SECS Initial set-up is now complete 9 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 10: Adjusting Limits

    Hold DOWN and STOP on To save lower limit, hold DOWN and position by pressing the UP or DOWN STOP. controller. button Motor Response Motor Response Approx. SECS 10 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 11: Adding Or Removing Controllers And Channels

    Press P2 on existing Press P2 on existing Press P2 on new controller. controller. controller. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor. 11 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 12: Favorite Positioning

    Send shade to favorite position Hold STOP on controller. Approx. Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. Motor Response Motor Response Motor Response 12 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 13: Sleep Mode

    RELEASE P1 Exit sleep mode Exit sleep mode once shade is installed. PRESS & RELEASE P1 button on motor head. Motor Response Approx. Motor Response MOTOR RUNS TO LIMIT 13 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 14: Troubleshooting

    (multiple motors respond) same channel. for programming purposes Place all other motors into sleep mode (ref to P1 function overview - section 3.2 and 10.1) 14 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor ROLLEASE ACMEDA...
  • Page 15 ROLLEASE ACMEDA AUSTRALIA Queensland Branch 110 Northcorp Boulevard, Unit 2/62 Borthwick Avenue, Broadmeadows VIC 3047 Murarrie QLD 4172 T +61 3 9355 0100 | F +61 3 9355 0110 ROLLEASE ACMEDA 200 Harvard Avenue Stamford, CT 06902 6320 T +1 203 964 1573 | F +1 203 964 0513...

Table of Contents