OptiPure ScaleX2 SX2-21 Installation, Operation & Maintenance Manual

Advertisement

Quick Links

DO NOT DISCARD - GIVE THIS MANUAL TO THE OWNER AFTER INSTALLATION
DO NOT DISCARD THIS MANUAL AFTER INSTALLATION. THIS MANUAL CONTAINS
IMPORTANT OPERATION, MAINTENANCE AND PRECAUTIONARY INFORMATION.
PLEASE PRESENT THIS MANUAL TO USER/OPERATOR/OWNER AFTER INSTALLATION.
IT IS STRONGLY ENCOURAGED THAT YOU READ THIS MANUAL BEFORE INSTALLING
SYSTEM TO ENSURE THE BEST POSSIBLE INSTALLATION.
INSTALLATION MUST CONFORM TO ALL LOCAL AND STATE PLUMBING CODES AND
REGULATIONS.
CONNECT SYSTEM TO COLD WATER SUPPLY ONLY. WATER TEMP. CAN NOT EXCEED
100°F/38°C.
SYSTEM MUST BE INSTALLED IN A VERTICAL AND UPRIGHT POSITION.
SCALEX2
SYSTEMS MUST NOT BE USED IN CONJUNCTION WITH POLYPHOSPHATE OR
®
ANY OTHER SCALE INHIBITOR.
DO NOT INSTALL FILTERS DOWNLINE FROM THE SCALEX2
BE THE LAST FILTER SYSTEM BEFORE THE EQUIPMENT.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN
QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
FAILURE TO CHANGE CARTRIDGES PER RECOMMENDED INTERVALS WITH OPTIPURE
REPLACEMENT CARTRIDGES MAY LEAD TO SYSTEM FAILURE AND PROPERTY DAMAGE.
Introduction
Your new OptiPure ScaleX2
tap water, providing optimum water characteristics for specified applications. Results in-
clude reduced equipment-maintenance requirements, longer equipment life and improved
quality and consistency of your products. Proper system installation and routine filter
changes ensure years of trouble-free operation and performance.
The OptiPure System is built with the finest and most advanced materials. Each system
is quality inspected and pressure-tested prior to shipment. With proper installation and
routine maintenance, you should have years of trouble-free operation.
Please refer to this manual when performing routine filter changes. The instructions make
periodic maintenance quick and easy, and ensure that you should receive maximum benefit
from your system.
System Specifications
Maximum Pressure: 125 psi/8.6 bar
Capacity: Change the CTO (pre-filter) cartridge at gallon rating, or at least every 6 months or
when pressure gauge needle enters the red zone on the outlet gauge while water is flowing
through the filter system under normal operating conditions. The SCLX2 cartridge does not
have a grain removal capacity; however, naturally occurring organics present in the water
will gradually degrade the effectiveness of this cartridge. Change the SCLX2 cartridge at
least once a year.
Installation Precautions
• Do NOT install system on line pressure above 125 psi.
• Do NOT install the system backwards with the feed water line connected to the outlet.
• Do NOT use liquid pipe compounds for fitting connections. USE two to three wraps of
teflon tape.
• Do NOT solder plumbing connections attached to filter housing or inlet valve. Inlet
valve and filter housing will be damaged by high temperature.
• Do NOT allow system to freeze. Turn off water supply to housing and drain housing if
temperature falls below 32°F.
• Do NOT install system in direct sunlight or where system is exposed to harsh
chemicals, or where it may be subjected to being struck by moving equipment, carts,
mops or any other item that may cause damage.
Installation, Operation & Maintenance Manual
Reduce Particulate, Chlorine, Taste, Odor & Scale
FoodService Filtration System will cleanse and condition the
®
Maximum Temperature: 100°F/38°C, Min.: 35°F/2°C
For ScaleX2
Models: SX2-21, SX2-22
®
SYSTEM. SCALEX2
®
MUST
®

Advertisement

loading

Summary of Contents for OptiPure ScaleX2 SX2-21

  • Page 1 Proper system installation and routine filter changes ensure years of trouble-free operation and performance. The OptiPure System is built with the finest and most advanced materials. Each system is quality inspected and pressure-tested prior to shipment. With proper installation and routine maintenance, you should have years of trouble-free operation.
  • Page 2 Do NOT mount the OptiPure system near any source of heat. Also, do not mount the system above any device or area that would be adversely affected by water.
  • Page 3 10. Connect tubing to equipment. Open all water supply valves and check for leaks. 11. If there are no leaks, turn on equipment and check for normal operation. 12. Attach the Service Log to the Installed OptiPure System and fill in install date. Operation With adequate pressure, normal operation of the ScaleX2 System is completely automatic.
  • Page 4 OptiPure warrants the quality of workmanship of their system components and assembly, except for replacement cartridges and membranes, for a period of 60 months. OptiPure Systems are designed, tested and certified with OptiPure cartridges. Use of replacement cartridges or parts other than those specified will void warranties and certifications, and may compromise equip- ment protection, water quality and cartridge life.

This manual is also suitable for:

Scalex2 sx2-22