Introduction

The Alaris GW 800 Volumetric Pump (herein after referred to as 'Pump') is a small lightweight volumetric infusion Pump that provides
accurate and reliable infusions over a range of rates . The ideal Pump for general care and critical care .
This Directions for use can be used with the following Alaris GW 800 800 Volumetric Pumps:-
• 800TIG2BGN1
• 800TIG2CZN1
• 800TIG2DEN1
• 800TIG2FRN1
• 800TIG2NLN1
• 800TIG2TRN1
• 800TIG2RWN1
To achieve the nominal performance stated in this DFU, BD strongly recommends use of Alaris GW 800 branded dedicated infusion sets .
Facilities intending to use non-dedicated infusion sets with the set detection mode disabled are advised to assess performance prior to
clinical use . If adequate performance is not achieved, then Alaris GW 800 branded dedicated infusion sets should be used or the Alaris
GW 800 Volumetric Pump should be re-calibrated . The use of a flow sensor is mandatory when the automatic set detection mode on the
Pump is disabled .
DISCLAIMER. This Pump has been tested and approved by BD for use only with BD dedicated infusion sets. In the
w
event the user is considering using infusion sets, not approved for use with the Alaris GW 800 Volumetric Pump,
the user should consult an authorized BD representative for compatibility and/or calibration information prior
to use. In no event, however, does BD make any representations or warranties concerning the adequacy and safe
performance of any non-dedicated infusion sets as it relates to the operation of the Pump and the accuracy of the
infusion.
In no event shall BD be liable for any damages of any kind or nature, including without limitation, direct or indirect,
special, consequential, or incidental damages arising from, or in connection with, the use of non-dedicated infusion
sets (Infusion sets not manufactured by BD), regardless of whether BD has been advised as to the possibility of such
use.

Intended Purpose

The Alaris GW 800 Volumetric Pump is intended for use by medical staff for the purpose of controlling infusion rate and volume .

Conditions for Use

The Alaris GW 800 Volumetric Pump should only be operated by medical staff competent in the use of automated volumetric pumps
and in the management of infusion therapy . Medical staff should determine the suitability of the device in their care area for its
intended purpose .
The user must be thoroughly familiar with the Pump and have been trained as per training document 0000CF02888.
w

Indications

The Alaris GW 800 Volumetric Pump is indicated for the infusion of fluids, medications, parenteral nutrition, blood and blood products
through clinically acceptable routes of administration; such as intravenous (IV), intra-arterial (IA), subcutaneous, epidural or irrigation of
fluid spaces . The Alaris GW 800 Volumetric Pump is indicated for use on adults and paediatrics .

Contraindications

The Alaris GW 800 Volumetric Pump is contraindicated for enteral therapies .