Parameters - ABB ACS355 Supplement Manual

High speed program (+n826)
Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

Parameters

All parameters
No.
Name/Value
11 REFERENCE
SELECT
1104 REF1 MIN
0.0...1400.0 Hz
/ 0...32000 rpm
1105 REF1 MAX
0.0...1400.0 Hz
/ 0...32000 rpm
12 CONSTANT
SPEEDS
1202 CONST
SPEED 1
0.0...1400.0 Hz
/ 0...32000 rpm
1203 CONST
SPEED 2
0.0...1400.0 Hz
/ 0...32000 rpm
1204 CONST
SPEED 3
Description
Panel reference type, external control location selection and
external reference sources and limits
Defines the minimum value for external reference REF1.
Corresponds to the minimum setting of the used source
signal.
Minimum value in rpm. Hz if parameter 9904 MOTOR CTRL
MODE setting is SCALAR: FREQ.
Example: Analog input AI1 is selected as the reference
source (value of parameter 1103 is AI1). The reference
minimum and maximum correspond to the 1301 MINIMUM
AI1 and 1302 MAXIMUM AI1 settings as follows:
REF1 MAX
(1105)
REF1 MIN
(1104)
1302
-REF1 MIN
(1104)
-REF1 MAX
(1105)
Defines the maximum value for external reference REF1.
Corresponds to the maximum setting of the used source
signal.
Maximum value in rpm. Hz if parameter 9904 MOTOR
CTRL MODE setting is SCALAR: FREQ. See the example
for parameter
1104 REF1
Constant speed selection and values.
Defines constant speed (or drive output frequency) 1.
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ.
Defines constant speed (or drive output frequency) 2.
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ.
Defines constant speed (or drive output frequency) 3.
Actual signals and parameters 17
REF (Hz/rpm)
AI1 signal (%)
1301
1301
1302
MIN.
Def/FbEq
0.0 Hz /
1 rpm
1 = 0.1 Hz
/ 1 rpm
E: 50.0 Hz
U: 60.0 Hz
1 = 0.1 Hz
/ 1 rpm
E: 5.0 Hz
U: 6.0 Hz
1 = 0.1 Hz
/ 1 rpm
E: 10.0 Hz
U: 12.0 Hz
1 = 0.1 Hz
/ 1 rpm
E: 15.0 Hz
U: 18.0 Hz

Advertisement

Table of Contents
loading

Table of Contents