9 Error messages
Error
Description
message
--ol-
Maximum load exceeded
Zeroing range exceeded due
to switching-on balance or
Err 4
pressing
max)
Err 5
Keyboard error
Value outside the A/D changer
Err 6
range
Err 10
No signal
Capacity of rechargeable
Lo bA
battery exhausted
Should other error messages occur, switch balance off and then on again. If the error
message remains inform manufacturer.
HFT-BA-e-1812
Possible causes
(normally 4%
Reduce load
Check whether the balance has
been damaged
Load attached
Overload during setting to zero
Improper operation of the balance
Damaged weighing cell
Damaged electronics
Distance emitter / receiver too
long
Emitter (connecting box) not
switched on
Recharge battery
39