COM2
Pin#
[RS-485 2 wire]
1
DATA-
2
DATA+
3
4
5
6
7
8
9
COM2
Pin#
[RS-485 2 wire]
1
DATA-
2
DATA+
3
4
5
6
7
8
9
Note: COM2 [RS-485 2W] and COM3 [RS-485 2W] support the Siemens
MPI 187.5K multi-point interface. However, only one COM port can be used
with the Siemens MPI interface at a time.
Note: COM1 RS232 RTS/CTS and COM3 RS232 cannot be used
simultaneously.
1010-1018 Rev 10
Serial Port Pinouts (cont.)
DE9S
COM2
COM3
[RS-485 4 wire]
[RS-485 2 wire]
RX-
RX+
TX-
TX+
GND
DATA-
DATA+
HMI5070NL, HMI5071L
HMI5070DL
HMI5097NXL
HMI5097DXL
DE9S
COM2
COM3
[RS-485 4 wire]
[RS-485 2 wire]
RX-
RX+
TX-
TX+
GND
DATA-
DATA+
HMI5102L and HMI5103L
CAN Bus
Pin#
(XL/DXL only)
1
2
3
4
5
6
CAN_L
7
CAN_H
8
9
COM1
Pin#
[RS-232]
1
2
RXD
3
TXD
4
5
6
7
RTS
8
CTS
9
www.maplesystems.com
DE9P
COM1
COM3 [RS-232]
[RS-232]
(DL/DXL only)
RXD
TXD
GND
RTS
TXD
CTS
RXD
GND
DE9P
COM3
[RS-232]
GND
TXD
RXD
GND