Technical Data

Auxiliary switches
Feedback
Power supply
Fail safe - Enerdrive
Power consumption
Control signal
Ingress protection
Running time through 90º
Torque
Electrical connection
Inlet bushing
Angle of rotation
Direction of rotation
Ambient temperature
Storage temperature
Relative Humidity
Weight

Dimensions

D
C
Caution
We strongly recommend that all neptronic® products be wired to a separate transformer and that transformer shall service only neptronic® products. This precaution will
prevent interference with, and/or possible damage to incompatible equipment.
When multiple actuators are wired on a single transformer, polarity must be observed. Long wiring runs create voltage drop which may affect the actuator performance.
1
Enerdrive System U.S.A. Patent #5,278,454
BT1S/070629

Feature:

• Mounts easy on round
& square shaft (with option –8).
• External clutch for manual adjustments.
• Maintenance free.
• Position indicator.
• Fail safe by Enerdrive System
(on model 60S, 65S & 80S).
• Auxiliary switches
(on model 20S & 80S).
BT100S BT105S BT120S BT200S BT205S BT220S BT160S BT165S BT180S BT260S BT265S BT280S
No
No
Yes (2)
No
Yes
No
110 to 130 VAC 50/60Hz
No
6 VA
3 wire / 2 position, 4 wire / 3 point floating
IP22 equivalent to Nema type 2,
IP54 equivalent to Nema type 3R if water tight inlet
bushings (not supplied NEP617) are installed
0 to 90 degrees, mechanically adjustable (factory set with 90º stroke)
Reversible, Clockwise (CW) or Counterclockwise (CCW) (factory set with CW direction)
Warning: Do not press the clutch when actuator is powered
A
B
Specification & Installation instructions
1
No
No
Yes (2)
No
Yes
No
220 to 250 VAC 50/60Hz
90 - 110 sec, (Fail-safe20-35 sec)
50 in.lb. [5,6 Nm] at rated voltage
18 AWG [0.8 mm
2 inlet bushing of 5/8 in [15.9 mm] & 7/8 in [22.2 mm]
-22ºF to +122ºF [-30º C to +50º C]
-22ºF to +122ºF [-30º C to +50º C]
5 to 95 % non condensing.
3 lbs. [1.4 kg]
Dimension
D model 00S, 05S & 20S
model 60S, 65S & 80S
No
No
Yes (2)
No
Yes
No
Yes
20VA Peak, 6VA
2 wire / 2 position, 4 wire / 3 point floating
IP22 equivalent to Nema type 2
2
] minimum
Inches Metric (mm)
A
1.50
B
3.26
C
6.60
3.01
3.72
Actuator
BT100S
BT105S
BT120S
BT160S
BT165S
BT180S
BT200S
BT205S
BT220S
BT260S
BT265S
BT280S
No
No
Yes (2)
No
Yes
No
38.1
82.8
167.5
76.4
94.5
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BT100S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Neptronic BT100S

  • Page 1 94.5 Caution We strongly recommend that all neptronic® products be wired to a separate transformer and that transformer shall service only neptronic® products. This precaution will prevent interference with, and/or possible damage to incompatible equipment. When multiple actuators are wired on a single transformer, polarity must be observed. Long wiring runs create voltage drop which may affect the actuator performance.
  • Page 2 Fix the bracket to the ductwork with #8 self-tapping screws. Wiring Diagrams Caution: Risk of electric shock. Remove power prior to connect. Models BT100S, 105S, 120S, 200S, 205S & 220S Models BT160S, 165S, 180S, 260S, 265S & 280S 3 wire / 2 position 2 wire / 2 position...

This manual is also suitable for:

Bt105sBt120sBt160sBt180sBt165sBt200s ... Show all

Table of Contents