Recommended Cabling; Status Indication; Power; Heartbeat - GAI-Tronics Clean Phone 295-702W Manual

Table of Contents

Advertisement

®
Clean Phone
VoIP Telephones
Outputs
Two outputs are provided for customer use. Terminations for these outputs are located on connector P10
(see Table 4 and Figure 9).

Recommended Cabling

Cable Use
LAN

Power

Inputs
Output contacts

Status Indication

Power
The Power LED located on the VoIP PCBA illuminates when power is applied to the telephone (see
Figure 9).

Heartbeat

The Heartbeat LED located on the VoIP PCBA flashes when the telephone is operational over the LAN
(see Figure 9).

EACT

The EACT LED located on the VoIP PCBA turns ON when VoIP PCBA is connected to an Ethernet
device and flashes when data is being transmitted (see Figure 9).

Programming

The installer must ensure that the network is configured to allow VoIP communications (using the SIP
protocol) between the desired locations before attempting to configure a Clean Phone
The general sequence to set up a Clean Phone
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-470G.docx
05/19
Table 4. Output Contacts—P10
Pin
Label
Description
C1
1
Common Output 1
NO1
2
Normally Open Output 1
C2
3
Common Output 2
NO2
4
Normally Open Output 2
Table 5. Recommended Cabling
Size and Type
Cat5 or Cat5e cable with an RJ45 connector
Two-conductor, No. 22 AWG is typical
Two-conductor, No. 22 AWG is typical
Two-conductor, No. 18 AWG is typical
®
VoIP telephone is as follows:
Pub. 42004-470G
Page 11 of 15
®
VoIP telephone.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clean phone 295-702f

Table of Contents