STARTUP / OPERATION
Key Functions:
• 2 ON/OFF regulators for HOT/COLD
• Single defrost and double evaporator
(heatings, modulated heaters, reverse cycle, hot gas)
• Evaporator fans and condenser fans
• Frame Heater
• AUX
• Light
• Door switch
• ON /OFF
• Deep cooling cycle
• Day / Night
• Diagnostics
• "Easy Map" programming
• Programmable inputs/outputs
• LINK2 local area network
• RS485 communication protocol: Modbus
• Compatible with Device Manager (DM)
• Compatible with Unicard and Multi-function key
2 - SPECIFICATIONS
TECHNICAL DATA
Classification:
Mounting:
Type of action:
Pollution class:
Material class:
Overvoltage category:
Nominal pulse voltage:
Temperature:
Power supply:
Power consumption:
Fire resistance category:
Software class:
RTC battery life:

FURTHER INFORMATION

INPUT CHARACTERISTICS
P/N 0515258_N
Measurement range:
electronic automatic control (not safety) device for incorporation
panel mounting
1.B
2
IIIa
II
2500V
Use: –5 ... +55°C - Storage: -30 ... +85°C
SMPS 100-240Va ±10% 50/60 Hz
5.5W max
D
A
In absence of external power, the clock battery will last 3 years.
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
NTC: -50.0°C ... +110°C; PTC: -55.0°C ... +150°C; PT1000: -60.0°C ... +150°C
(on 3-digit display with +/- sign)