Motor Flash Codes - Pentair Sta-Rite EcoSelect Enviromax 800 Owner's Manual

Variable speed pool pump
Table of Contents

Advertisement

► If a fault develops with the motor, the error light will flash a number of times as per the following
table. Faults can be cleared by resetting power to the motor. If faults persist contact your Pentair
service agent.

Motor Flash Codes

1
2
Microcontroller
Mains under
failure
voltage
Microcontroller
The mains
is continually
voltage has
rebooting.
dropped
below
180VAC.
Troubleshooting
The variable speed motor is a sophisticated and highly technical device. Should a fault
occur with the motor, it cannot be serviced and must be replaced by a certified Pentair
service agent.service agent or similarly qualified personnel in order to avoid a hazard.
Warranty is void if unauthorised modifications are made to any component.
No. of flashes
3
4
Over
Over
Temperature
Current
Motor
Over current
temperature
protection
has exceeded
has tripped.
maximum
Speed will
limit.
reduce until
Speed will
motor
reduce
returns
until motor
to
returns to
acceptable
acceptable
condition.
temperature.
5
6
Mains over
Output shaft
voltage
seized
The mains
Motor shaft
voltage
seized due
has risen to
to blockage
above
in pump
269VAC
or fan.
7
8
Self check
Motor
failed
fault
One or more
One or more
of the
of the phases
self-tests
has become
failed during
disconnected.
start up or
while
running.
14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents