Danfoss PLUS+1 DP570 Series Technical Information page 13

Mobile machine displays
Table of Contents

Advertisement

Technical Information
DP570 Series Displays
Inputs/outputs
©
Danfoss | January 2017
High range frequency input PPU (continued)
Description
Minimum
Worst case error
Rising voltage
11.83 V
threshold
Falling voltage
5.61 V
threshold
Input impedance
108 kΩ
Input impedance
13.0 kΩ
Input impedance
6.9 kΩ
Resistance input
Description
Range
Resolution
Source current
*
When configured as a resistance/rheostat/temp sensor input, the device will provide up to 3.76 mA current to an
external load which can then be measured. The equation for calculating AD counts for a given load is: AD counts =
(2338* RL / (RL + 1330)).
Rheostat inputs: AD counts and load relationship
2500
2000
1500
1000
500
0
0
2000
4–20 mA input
Description
Range
Resolution
Typical
Maximum
1.296 mV
26.55 V
18.89 V
110 kΩ
112 kΩ
13.2 kΩ
13.4 kΩ
7 kΩ
7.1 kΩ
Unit
Minimum
Maximum
Ω
0
10000
mA
0
3.6
4000
6000
8000
Load Resistance
(
)
Unit
Minimum
Maximum
mA
0
54.3
μA
21
Comment
Over the full
temperature range
-30º C to +60º C (-22º
F to +140º F)
Voltage required for
frequency input to
read high
Voltage required for
frequency input to
read low
No pull up or pull
down
Pull up to +5V or pull
down to ground
Pull to +2.5V
Comment
*
AD counts
10000
Comment
L1328765 | BC00000231en-US0701 | 13
P200167

Advertisement

Table of Contents
loading