Danfoss PLUS+1 DP570 Series Technical Information
Danfoss PLUS+1 DP570 Series Technical Information

Danfoss PLUS+1 DP570 Series Technical Information

Mobile machine displays

Advertisement

Quick Links

Technical Information
PLUS+1® Mobile Machine Displays
DP570 Series
powersolutions.danfoss.com

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss PLUS+1 DP570 Series

  • Page 1 Technical Information PLUS+1® Mobile Machine Displays DP570 Series powersolutions.danfoss.com...
  • Page 2 Vault memory, removed reference to USB port (DP570 does not have one) March 2015 Various February 2015 Converted to Danfoss layout; Ingress Protection (IP) rating updated; new drawing with updated bracket and seal for flush mounted option December 2013 Model feature November 2013 Screw lengths and torque...
  • Page 3: Table Of Contents

    Testing criteria....................................17 Maintenance guidelines LCD module ....................................19 Installation Dimensions.......................................20 Two mounting options................................21 Flush mounted..................................21 Stand-alone on post................................21 Pin assignments....................................22 Machine wiring guidelines................................. 23 Machine welding guidelines..............................23 L1328765 | BC00000231en-US0701 | 3 © Danfoss | January 2017...
  • Page 4: Literature References

    ® hardware modules • How to upload and download tuning parameters • How to use the PLUS+1 ® Service Tool Latest version of technical literature Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/ L1328765 | BC00000231en-US0701 © Danfoss | January 2017...
  • Page 5: User Liability And Safety Statements

    User liability and safety statements OEM responsibility The OEM of a machine or vehicle in which Danfoss products are installed has the full responsibility for all consequences that might occur. Danfoss has no responsibility for any consequences, direct or indirect, caused by failures or malfunctions.
  • Page 6: Dp570 Series Displays

    Anyone in receipt of this program may obtain the complete corresponding source code from Danfoss for a period of three years after the last shipment of this product and/or spare parts by going on line at http://www.danfoss.com...
  • Page 7: Ordering Information

    C—Real time clock Code Description D—Flash memory/application key Code Description 512 MB/without application key E—Application log (vault memory) Code Description 16 MB F—Video input options Code Description None One video input L1328765 | BC00000231en-US0701 | 7 © Danfoss | January 2017...
  • Page 8: Related Products

    GUIDE Professional Software 11179523 (Includes 1 year of software updates, a single user license, (annual renewal with 11179524 to keep the software Service and Diagnostic Tool and Screen Editor) updates) Post mounting kit 11144122 L1328765 | BC00000231en-US0701 © Danfoss | January 2017...
  • Page 9: Inputs/Outputs

    Pull down to ground Input impedance with pull-up kΩ 14.1 ± 0.2 Pull up to +5 V Input impedance with pull-up/down kΩ 7.3 ± 0.1 Pull up to +2.5 V L1328765 | BC00000231en-US0701 | 9 © Danfoss | January 2017...
  • Page 10 5.43 — Resolution μA — Worst case error Over the full temperature range -30º C to +60º C (-22º F to +140º F) Input impedance Ω 100.76 ± 0.1 — L1328765 | BC00000231en-US0701 10 | © Danfoss | January 2017...
  • Page 11: High Range Input Impedance For Analog Inputs

    High range input impedance for analog inputs 70000 70000 63500 57000 50500 44000 Rxhi nopull.HiV (Vin) Rxhi pullup.HiV (Vin) 37500 Rxhi pulldn.HiV (Vin) Rxhi pullboth.HiV (Vin) 31000 24500 18000 11500 5000 5000 Voltage L1328765 | BC00000231en-US0701 | 11 © Danfoss | January 2017...
  • Page 12: Multifunction

    Description Minimum Typical Maximum Comment Minimum discernible 0 mV — 130 mV — voltage Maximum discernible 34.704 V 36 V 37.296 V — voltage Precision — — 14.3 mV — L1328765 | BC00000231en-US0701 12 | © Danfoss | January 2017...
  • Page 13 Rheostat inputs: AD counts and load relationship 2500 2000 1500 1000 AD counts 2000 4000 6000 8000 10000 Load Resistance Ω P200167 4–20 mA input Description Unit Minimum Maximum Comment Range 54.3 — Resolution μA — L1328765 | BC00000231en-US0701 | 13 © Danfoss | January 2017...
  • Page 14: Encoder

    The use of a different power supply for the camera can create “noise” on the signal line which will affect its functionality. L1328765 | BC00000231en-US0701 14 | © Danfoss | January 2017...
  • Page 15: Controller Area Network (Can) Specifications

    One of them can be used either as CAN or a digital-analog input. CAN communication Description Unit Minimum Maximum Comment Available baud rates 1000 The default baud rate is 250kbit. Maximum input voltage — range L1328765 | BC00000231en-US0701 | 15 © Danfoss | January 2017...
  • Page 16: Memory

    PLUS+1 ® Service Tool to extract the logged data. Accessing non-volatile or application log memory can delay the service tool scan. L1328765 | BC00000231en-US0701 16 | © Danfoss | January 2017...
  • Page 17: Product Ratings

    IEC 60068-2-1, IEC 60068-2-2 Temperature change IEC 60068-2-14 Moisture ingress IEC 60529 Sunlight radiation ISO 16750-4 Temp humidity voltage IEC 60068-2-38 Mechanical Condition Rating Vibration, resonance IEC 60068-2-6 Vibration, operation IEC 60068-2-64 L1328765 | BC00000231en-US0701 | 17 © Danfoss | January 2017...
  • Page 18 Technical Information DP570 Series Displays Product ratings Mechanical (continued) Condition Rating Bump IEC 60068-2-29 Shock IEC 60068-2-27 Free fall IEC 60068-2-32 L1328765 | BC00000231en-US0701 18 | © Danfoss | January 2017...
  • Page 19: Maintenance Guidelines

    The protective glass will break if hit with a hard or heavy object. If the protective glass is broken, remove the display from your machine then return the display to Danfoss to be serviced. Clean the display's housing and protective glass with a clean, soft, damp cloth, or mild dishwashing detergent because abrasive pads or solvents, including alcohol, benzene, and paint thinner can cause scratching and discoloration.
  • Page 20: Installation

    Technical Information DP570 Series Displays Installation Dimensions DP570 dimensions in millimeters 7.00 173.40 115.20 36.20 169.40 144.78 86.40 4 x Ø 8 39.70 75.00 49.2 63.7 kwa1422303242511 L1328765 | BC00000231en-US0701 20 | © Danfoss | January 2017...
  • Page 21: Two Mounting Options

    1. 4X insert for M4 screw x 0.7 thread x 11 maximum depth 2. Post mount cover 3. M4X18 screws with Post mount cover lock washers (4X) 4. Maximum bracket thickness using screws provided with cover L1328765 | BC00000231en-US0701 | 21 © Danfoss | January 2017...
  • Page 22: Pin Assignments

    C1-P5 CAN Shield C2-P5 C1-P6 CAN1 High + or DIN/AIN C1-P7 CAN1 Low – or DIN/AIN C1-P8 DIN/AIN/4–20 mA C1-P9 DIN/AIN/4–20 mA C1-P10 Multi-function Input C1-P11 Multi-function Input C1-P12 DOUT L1328765 | BC00000231en-US0701 22 | © Danfoss | January 2017...
  • Page 23: Machine Wiring Guidelines

    Do not use electrical components to ground the welder. • Clamp the ground cable for the welder to the component that will be welded as close as possible to the weld. L1328765 | BC00000231en-US0701 | 23 © Danfoss | January 2017...
  • Page 24 Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.

Table of Contents