Setting parameters for blocks
3.5 Programming the Ident profile
The "PHYSICAL-WRITE" command
The optical reader systems MV400/MV500 have further commands that can be transferred
with the "PHYSICAL-WRITE" command.
Table 3- 78
PHYSICAL-WRITE
CMD
OFFSET
ADDR_TA
BUFFER
G
0x71
Offset in
0x0000
the
"TXREF"
send
buffer
Table 3- 79
Address
0x0000
0x0001
Table 3- 80
Address
0x0000
100
LEN_DATA
Length of data to be sent to the read-
er:
0x02
0x01
Match string length + 3
0x01
0x01
0x01
Total length of the XMATCH user
data + 4
0x07
Command data area "TXREF" command identifier 0x01 (program change)
Value
0x01
0x00 ... 0x0F
Command data area "TXREF" command identifier 0x02 (activate read program number)
Value
0x02
TXREF
Sub command with data to be sent to the read-
er. The first "SINT" contains the command
identifier:
0x01 = Program change
0x02 = Activate read program number
0x03 = Write match string
0x04 = Activate read match string
0x05 = Set DISA bit
0x06 = Reset DISA bit
0x07 = Write trigger-synchronized match
string (XMATCH)
0x08 = Set Digital Out
Meaning
"Program change" command identifier
Number of the program
Meaning
"Read program number" command identifier
Ident profile and Ident blocks, standard function for Ident systems