3v control system. zone controller pressure dependent control
Hide thumbs Also See for VVT 33ZCVVTZC-01:
Table of Contents

Advertisement

DESCRIPTION
Commissioning Mode
Auto-Disable Timer
All Zone Dampers to Max
All Zone Dampers to Min
Position Single Zone
Zone 1 Damper Position
Zone 2 Damper Position
Zone 3 Damper Position
Zone 4 Damper Position
Zone 5 Damper Position
Zone 6 Damper Position
Zone 7 Damper Position
Zone 8 Damper Position
Zone 9 Damper Position
Zone 10 Damper Position
Zone 11 Damper Position
Zone 12 Damper Position
Zone 13 Damper Position
Zone 14 Damper Position
Zone 15 Damper Position
Zone 16 Damper Position
Zone 17 Damper Position
Zone 18 Damper Position
Zone 19 Damper Position
Zone 20 Damper Position
Zone 21 Damper Position
Zone 22 Damper Position
Zone 23 Damper Position
Zone 24 Damper Position
Zone 25 Damper Position
Zone 26 Damper Position
Zone 27 Damper Position
Zone 28 Damper Position
Zone 29 Damper Position
Zone 30 Damper Position
Zone 31 Damper Position
Zone 32 Damper Position
Bypass Damper Position
Bypass Pressure Sensor
Bypass Pressure Setpoint
AUTO DISABLE TIMER — This variable displays the num-
ber of minutes remaining before the system commissioning
mode will be automatically disabled. System commissioning
mode is automatically disabled after one hour of no activity in
this table. The Auto Disable Timer is reset each time a value is
changed in this table.
Auto Disable
Timer:
Display Range
Network Access None
ALL ZONE DAMPERS TO MAX — This variable displays
whether the Linkage Coordinator zone controller has been
directed to set all of its linked zone controllers to their config-
ured Cool Maximum Positions (Damper Service Configuration
Table). If this decision is forced to Enable, the Linkage Coordi-
nator zone controller will set all system zone dampers to their
configured Cool Maximum Positions and display the values in
Zone (1-32) Damper Position variables. At this time if any of
the Zone (1-32) Damper Position variables are forced, the new
position will be written to the zone's Cool Maximum Position
and Heat Maximum Position configuration values and the zone
will be repositioned to this new maximum position.
Table 19 — System Commissioning Maintenance Table
VALUE
Disable
0.0
Disable
Disable
Disable
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.00
0.00
0 to 60 min
UNITS
STATUS
Enable/Disable
Min
Enable/Disable
Enable/Disable
Enable/Disable
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
%OPEN
in H2O
in H2O
NOTE: If this zone controller is not the Linkage Coordinator,
enabling this variable will have no effect.
All Zone
Dampers to Max: Display Range
Network Access Read/Write
ALL ZONE DAMPERS TO MIN — This variable displays
whether the Linkage Coordinator zone controller has been
directed to set all of its linked zone controllers to their config-
ured Cool Minimum Positions (Damper Service Configuration
Table). If this decision is forced to Enable, the Linkage Coordi-
nator zone controller will set all system zone dampers to their
configured Cool Minimum Positions and display the values in
Zone (1-32) Damper Position variables. At this time if any of
the Zone (1-32) Damper Position variables are forced, the new
position will be written to the zone's Cool Minimum Position
and Heat Minimum Position configuration values and the zone
will be repositioned to this new minimum position.
NOTE: If this zone controller is not the Linkage Coordinator,
enabling this variable will have no effect.
All Zone
Dampers to Min: Display Range
Network Access Read/Write
46
FORCE
NAME
SCMOD
SCTIME
ZD_MAX
ZD_MIN
ZD_SING
ZD_POS01
ZD_POS02
ZD_POS03
ZD_POS04
ZD_POS05
ZD_POS06
ZD_POS07
ZD_POS08
ZD_POS09
ZD_POS10
ZD_POS11
ZD_POS12
ZD_POS13
ZD_POS14
ZD_POS15
ZD_POS16
ZD_POS17
ZD_POS18
ZD_POS19
ZD_POS20
ZD_POS21
ZD_POS22
ZD_POS23
ZD_POS24
ZD_POS25
ZD_POS26
ZD_POS27
ZD_POS28
ZD_POS29
ZD_POS30
ZD_POS31
ZD_POS32
BDP
BPSENS
BPSETP
Enable/Disable
Enable/Disable