MSA S-Cap-Air Operating Manual page 9

Compressed air escape apparatus with hood
Hide thumbs Also See for S-Cap-Air:
Table of Contents

Advertisement

MSA
After use the unit must be cleaned, disinfected and checked for damage
(à Section 6); the cylinder should be refilled (à Section 4).
Afterwards put the unit into the carry bag (à Section 5), seal the carry
bag with leads and check the bag (à Section 6).
If a unit has been made ready but not used, it must at least be checked
visually for damage.
Checking the indicator in the hood
(9) Check the warning indicator in the hood's field
of vision:
GREEN:
Air supply in the hood is correct.
RED:
End of use.
Attention!
The indicator changes to RED when the air
supply from the cylinder is coming to an end.
The CO2 concentration in the hood then
increases and the hood must be removed.
Adjustment of the body belt
(10) Close and tighten the body belt.
Starting the escape
(11) Escape calmly and smoothly. Do not take off
the hood until the danger area has been
vacated.
S-Cap-Air
USE
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents