Groen Vortex 100 VRC-6E Operator's Manual

Groen Vortex 100 VRC-6E Operator's Manual

Connectionless steamer, domestic, self contained, electric heated, capacity 3/6 steamer pans per cavity

Advertisement

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODELS VRC-3E
& VRC-6E
VORTEX100
CONNECTIONLESS
STEAMER
· Self Contained
· Electric Heated
· Capacity:
VRC-3E=3 Steamer Pans Per Cavity
VRC-6E=6 Steamer Pans Per Cavity
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 148673, REV. H (5/08)
PART NUMBER 148673, REV. G (09/07)
Domestic
®
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
groen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vortex 100 VRC-6E and is the answer not in the manual?

Questions and answers

Summary of Contents for Groen Vortex 100 VRC-6E

  • Page 1 Unified Brands recommends referencing our product line websites, 1055 Mendell Davis Drive unifiedbrands.net, for the most updated product information and specifications. Jackson, MS 39272 888-994-7636, fax 888-864-7636 groen.com PART NUMBER 148673, REV. H (5/08) PART NUMBER 148673, REV. G (09/07)
  • Page 2: Operator Warnings

    RETURNED TO ITS PROPER LOCATION. WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
  • Page 3: Table Of Contents

    NATIONAL FIRE PROTECTION ASSOCIATION 333 Pfingsten Road 60 Batterymarch Park Northbrook, Illinois 60062 Quincy, Massachusetts 02269 NFPA/70 The National Electrical Code Website Address: www.groen.com NATIONAL SANITATION FOUNDATION NSF INTERNATIONAL 3475 Plymouth Road 789 N. Dixboro Rd. Ann Arbor, Michigan 48106 P.O. Box 130140 Ann Arbor, Michigan 48113-0140 148673 REV.
  • Page 4: Equipment Description

    THE VRC-3E WEIGHS 150 POUNDS (68 KG). If damage is evident, notify the local carrier THE VRC-6E WEIGHS 170 POUNDS (77 KG). immediately and file a damage claim. Groen YOU SHOULD GET HELP AS NEEDED TO LIFT assumes no liability for damage incurred in transit.
  • Page 5: Installation And Start-Up

    OM-VRC-3E/VRC-6E Installation and Start-Up CAUTION DO NOT INSTALL THE UNIT WITHIN 2 INCHES OF A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FAT FRYER, CHARBROILER OR KETTLE). Electrical Supply Connection - Observe all local, national, or other applicable codes. Branch Circuit Protection Three phase models of the Vortex™...
  • Page 6 OM-VRC-3E/VRC-6E Water Connection(s) - Units Manual Filled Stacking Units Instructions water connection is needed. The water will be Remove drain containment pan from the bottom of unit(s). Unscrew to remove adjustable legs from poured directly into the water cavity reservoir. Avoid base of Vortex unit(s).
  • Page 7 OM-VRC-3E/VRC-6E 148673 REV. G OM-VRC-3E/VRC-6E...
  • Page 8: Operation

    OM-VRC-3E/VRC-6E Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. Controls he HI TEMP (error code 6) indicator comes on when the bottom of the water Operator controls are on the front right of the unit. reservoir becomes too hot.
  • Page 10: Cleaning

    OM-VRC-3E/VRC-6E Cleaning To keep your VRC-3E or VRC-6E Connectionless Steamer in proper working condition, use the following procedure to clean the unit. Suggested Tools Use a mild detergent to wipe down the steamer cavity, the floats on the inside back panel wall Mild detergent and the pan racks.
  • Page 11: Maintenance

    Troubleshooting This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel.
  • Page 12: Drain Kit Installation Instructions

    OM-VRC-3E/VRC-6E WATER DRAIN KIT INSTALLATION INSTRUCTIONS 1-Remove all parts from shipping cartons. 4- Test to ensure the final assembly of the drain line allows the water to flow freely. WARNING: DISCONNECT POWER BEFORE Loops or kinks in the hose will cause back pressure which INSTALLING may cause the door to pop open during draining.
  • Page 13: Drain Kit Diagram

    OM-VRC-3E/VRC-6E 148673 REV. G OM-VRC-3E/VRC-6E...
  • Page 14: Racks, Pan Installation Instructions

    OM-VRC-3E/VRC-6E PAN RACKS FOR SINGLE STANDS ONLY INSTALLATION INSTRUCTIONS STAND, BULLET FEET OR CASTERS HOLES TO BE ALIGNED WITH THREADED HOLES HOLES TO BE ALIGNED ON THE BOTTOM OF STEAMER WITH THREADED HOLES ON THE BOTTOM OF STEAMER STAND CROSS MEMBER HOLE FOR RACK BOTTOM WIRE.

This manual is also suitable for:

Vortex 100 seriesVortex 100 vrc-3e

Table of Contents