MDS 05-4846A01, Rev. D
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8461-MDS-UP-SD9-MS2ES-Upgrade-Key-SD9-MS-to-SD9-ES.aspx
IC ID:
FCC Emission Designators (SD2):
6.25 kHz B/W (MODEM 4800F):
12.5 kHz B/W (MODEM 9600,
19200N):
25.0 kHz B/W (MODEM 19200):
5.0 kHz B/W (MODEM 3200):
15.0 kHz B/W (MODEM 9600M,
19200E):
FCC Emission Designators (SD4):
6.25kHz B/W (MODEM 4800F):
12.5 kHz B/W (MODEM 9600,
9600M, 4800):
25.0 kHz B/W (MODEM 19200):
FCC Emission Designators (SD9):
12.5 kHz B/W (MODEM 9600,
9600M, 4800):
25.0 kHz B/W (MODEM 19200):
DATA CHARACTERISTICS
Signaling Types:
COM2 Data Rates:
Data Latency:
PRIMARY POWER
Voltage:
NOTE: Early SD4 models supported 10.5 to 16 Vdc power, not 10 to 30 Vdc. Check the
labeling above the power connector to confirm the operating range for your unit.
TX Supply Current (Typical):
RX Supply Current (Typical):
Fuse:
ENVIRONMENTAL
Humidity:
Temperature Range:
Weight (nominal):
Transceiver Dimensions:
Mean Time Between Failure
(MTBF):
DIAGNOSTICS INTERFACE
Signaling Standard:
All specifications are subject to change without notice or obligation.
SD Series Technical Manual
SD2: 101D-SD2
SD4: 101D-SD4
SD9: 101D-SD9
3K24F1D, F2D, F3D
9K322F1D, F2D, F3D
16K8F1D, F2D, F3D
2K80F1D, F2D, F3D
8K15F1D, F2D, F3D
6K00F1D, F2D, F3D
11K2F1D, F2D, F3D
20K0F1D, F2D, F3D
10K6F1D, F2D, F3D
16K2F1D, F2D, F3D
RS-232/485; DB-9 Female connector
Ethernet 10/100 Mbps; RJ-45F connector
300–115200 bps, asynchronous
11 ms typical (transparent)
10.0 to 30 Vdc (Negative ground only)
2.5 Amperes maximum @ 5 Watts RF Output
Operational—125 mA, Nominal
Sleep—<10 mA typical @ 13.8 Vdc
5-Ampere, internal
SD2: 95% at 40°C (104°F), non-condensing
SD4: 95% at 70°C (158°F), non-condensing
SD9: 95% at 40°C (104°F), non-condensing
–40 to 70 degrees C (–40°F to 158°F)
1.22 lbs. (0.55 kg)
6.5" long (16.51 cm), 4.625" wide (11.75 cm),
1.5" High (3.81 cm)
Consult factory for on-file data
RS-232 (COM1, DB-9F connector)
RS-232/RS-485 (COM2, DB-9F connector)