IP Configuration

MDS 05-4846A01, Rev. D
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8461-MDS-UP-SD9-MS2ES-Upgrade-Key-SD9-MS-to-SD9-ES.aspx
—The
COM2
Mode
mode. The default is RS-232.
—The default data rate for
Baud Rate
be set to any of the following speeds: 300, 1200, 2400, 4800,
9600, 19200, 38400, 57600, 115200.
—The default data format for the transceiver is 8 char-
Data Format
acter bits, no parity, and 1 stop bit (8N1). A number of settings are
possible as listed below:
8 character bits, no parity, 1 stop bit (Default)
8 character bits, no parity, 2 stop bits
8 character bits, odd parity, 1 stop bit
8 character bits, odd parity, 2 stop bits
8 character bits, even parity, 1 stop bit
8 character bits, even parity, 2 stop bits
7 character bits, no parity, 1 stop bit
7 character bits, no parity, 2 stop bits
7 character bits, odd parity, 1 stop bit
7 character bits, odd parity, 2 stop bits
7 character bits, even parity, 1 stop bit
7 character bits, even parity, 2 stop bits
—The transceiver's buffer provides a way of handling data
Buffer
"over-runs," where more data is passing through the
than can be immediately handled by the unit. When the buffer is
on, any such data is stored up and processed in the appropriate
order. Available selections are
.
OFF
—This setting controls the device behavior of x710 legacy
Device
radios. It does not apply to packet or Ethernet radios, and may be
disregarded for these models.
—Any combination of the three Virtual Radio
Talk on/Listen to
Channels may be entered in these menu fields. For more informa-
tion on how these settings are used, refer to the SD Serial/Telnet
Management Supplement, Part No. 05-6193A01 more informa-
tion.
The IP Configuration Menu contains various settings for the IP data
stream. Each item is listed below along with instructions for making
changes. Note that the bottom of the screen displays the current settings
that have been applied to the radio in a read-only fashion.
SD Series Technical Manual
port can operate in either RS-232 or RS-485
is 9600 bps, but it may
COM2
Data Handling ON
port
COM2
or
Data Handling