4.3.1.6

NETWORK

The following table details the parameters of the NETWORK menu:
PARAMETER
PARAMETER VALUES REQUIRED OPTIONS REMARKS
STATUS
IP address
Product type
MAC address
ROLE
Offline
Power master
Master
Slave
Custom
ROOM NUMBER 1
...
7
IP SETTINGS
Auto (DHCP)
Direct-Link
Manual
WAKE-ON-LAN
No
Only if PoE
Yes
POWER OFF
Yes
COMMAND
No
38
The A1.5 SETUP >> NETWORK menu allows knowledge and customization of the
network related parameters of the unit. Accessible parameters are:
- STATUS:
- ROLE:
- ROOM NUMBER:
- IP SETTINGS:
- WAKE-ON-LAN:
- POWER OFF COMMAND:
Connection to a
List of CH Precision devices and Android remote controls detected
router via its RJ-45
by the A1.5 (product type, IP and MAC addresses)
Ethernet port
Read Only parameters
Connection to a
When physically connected to a network, the A1.5 can ignore this
router via its RJ-45
network (offline) or connect to it as being the master or as a slave.
Ethernet port (on
This networking facility allows information sharing among CH
the Control board).
products.
Connection to a
Define the room in which room the A1.5 is (for multiroom).
router via its RJ-45
This prevents CH Precision units connected to the same network but
Ethernet port
located in different systems/rooms to interact with each others.
Connection to a
Auto should be selected if the A1.5 is connected to a router with
router via its RJ-45
DHCP server feature.
Ethernet port
Connection to a
If No is selected, the A1.5 can't be woken up by the app. Standby
router via its RJ-45
mode will consume less than 0.5W.
Ethernet port
When Only if PoE is selected, the A1.5 can only be waken by the
app if connected to a Power-over-Ethernet switch. Standby mode
will draw less than 0.5W from the mains plug.
If Yes is selected, the A1.5 can always be woken up by the app.
Standby mode will draw a couple of watts from the mains plug.
Connection to a
Select No to make the A1.5 ignore Power Off commands from the
router via its RJ-45
network.
Ethernet port
Details of NETWORK menu parameters
A1.5 User Manual
Listing of all CH products detected
Defines how the A1.5 interacts with other devices on
the network
Group units connected to a single network by room
Low-level network configuration
Select how the unit can be powered on from the
network
Select if the unit can be powered off from the network
Rev 1.0