Chapter 3: Set-Up & Programming
displayed in the input image table as:
35
;high word
111
;low word
Note: If using Configuration 6, the resolver 1 position is displayed only as one word. Therefore,
the new data format does not apply to this position.
With the new data format option selected, the position can range from 0 to 32767999.
NOTE: All reserved locations should be set to 0.
Command 1: Configuration
The 1746R PLC Resolver Interface Module can be configured for 6 different applications:
Single axis, single turn resolver with no turns counting and one brake monitor input.
Multi-turn dual resolver with no inputs.
Single axis, single turn resolver with turns counting and one reset-to-preset input.
Two axis, two single turn resolvers with turns counting and two reset-to-preset inputs.
Multi-turn dual resolver with one reset-to-preset input.
Two axis, two single turn resolvers; one with no turns counting and one brake
monitor input; the other with turns counting and one reset-to-preset input.