When the position scaling data has been acknowledged for resolver 1, the program will copy the position
scaling command for resolver 2 into the output image table. This resolver is set up for a scale factor of 360 with
no turns counting. This will continue until the command has been acknowledged.
WHEN COPY OF THE RESOLVER 1 COMMAND IS COMPLETE, SET THE STATE FLAG TO CONFIGURE
RESOLVER 2
Res 1 Config Bit Set
N10:0
0004
1
COPY THE COMMAND TO CONFIGURE THE RESOLVER 2 WITH
SCALE FACTOR AND TURNS COUNTING INFORMATION
Res 2 Config Bit Set
Ack Bit Cleared
N10:0
0005
2
When the position scaling data has been acknowledged for resolver 2, the program will copy the reset-to-preset
command into the output image table. The reset-to-preset value for resolver 1 is set to 100 and the reset-to-
preset value for resolver 2 is set to 180. The program will wait for the acknowledge bit to be set.
WHEN COPY OF THE RESOLVER 2 COMMAND IS COMPLETE, SET THE STATE FLAG TO CONFIGURE
RESET-TO-PRESET
Ack Bit Set
Res 2 Config Bit Set
N10:0
0006
2
COPY THE COMMAND TO CONFIGURE THE RESET-TO-PRESET
Reset-to-Preset
Config Bit Set
N10:0
0007
3
17
Spec Tech Industrial Electric
www.spectechind.com
Ack Bit Set
Program Bit Set
I:1
O:1
15
15
OTHER
OTHER
I:1
15
OTHER
Program Bit Set
O:1
I:1
15
15
OTHER
OTHER
Ack Bit Cleared
I:1
15
OTHER
Installation & Programming Manual
www.spectechind.com
888-773-2832
Chapter 4: Application Examples
MOV
Move
Source
4
4 <
Dest
N10:0
0 <
Clear Program Bit
O:1
( U )
15
OTHER
COP
Copy File
Source
#N7:20
Dest
#O:1.0
Length
8
MOV
Move
Source
8
8 <
Dest
N10:0
0 <
Clear Program Bit
O:1
( U )
15
OTHER
COP
Copy File
Source
#N7:30
Dest
#O:1.0
Length
8