Download Print this page

Procedure To Remove Fan Motor And Fan Rotor - Daikin FAQ71BVV1B Service Manual

Removal procedure, 3/4 hp class, indoor unit, inverter, wall mounted type, heat pump
Hide thumbs Also See for FAQ71BVV1B:

Advertisement

Si281302

6. Procedure to Remove Fan Motor and Fan Rotor

Procedure
Step
Removing the front grille in
accordance with "Removal
of Front Grille".
Removing the
El. compo. box in
accordance with "Removal
of El. compo. Box".
1. Removing the fan motor
1
Insert a Phillips tip
screwdriver into the air
outlet and remove the
screws fixing the fan
motor and fan rotor.
(The screws can be
removed without
removing of horizontal
blade.)
Remove the 2 screws
2
on the bearing cover (1)
and (2) and dismantle
the covers.
3
Take out the fan motor
sideways.
2. Removing the fan rotor
Removing the heat
exchanger in accordance
with "Removal of Heat
Exchanger".
Remove the 2 screws
1
to dismantle the rotor
cover.
Pull the fan rotor out.
2
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Fan rotor
Procedure to Remove Fan Motor and Fan Rotor
Bearing cover (1)
Bearing cover (2)
Fan motor
Rotor cover
Points
7

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Faq100bvv1b