vacuubrand MD 12 VARIO select Instructions For Use Manual

vacuubrand MD 12 VARIO select Instructions For Use Manual

Diaphragm pump
Hide thumbs Also See for MD 12 VARIO select:

Advertisement

Quick Links

Technology for Vacuum Systems
D
iaphragm pump
MV 10 VARIO select
MD 12 VARIO select
ME 16 VARIO select
Instructions for use
Original instructions
EN
OI no.: 20901121

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MD 12 VARIO select and is the answer not in the manual?

Questions and answers

Summary of Contents for vacuubrand MD 12 VARIO select

  • Page 1 Technology for Vacuum Systems iaphragm pump MV 10 VARIO select MD 12 VARIO select ME 16 VARIO select Instructions for use Original instructions OI no.: 20901121...
  • Page 2 +49 9342 808‑5550 ƒ Service +49 9342 808‑5660 Fax: +49 9342 808‑5555 Email: info@vacuubrand.com Web: www.vacuubrand.com Thank you for purchasing this product from VACUUBRAND GMBH + CO KG . You have chosen a modern and techni- cally high quality product. 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 3: Table Of Contents

    Content Table of conTenT Introduction User information ....... . . 5 1.2 About this document.
  • Page 4 Content Commissioning (operation) 5.1 Switch on ........37 5.2 Operation .
  • Page 5: Introduction

    We reserve the right to make technical changes in the course of ƒ continuous product improvement. Copyright The content of this manual is protected by copyright. Only copies Copyright © for internal use are allowed, e.g., for professional training. © VACUUBRAND GMBH + CO KG 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 6: About This Document

    If your manual is incomplete, you can request a replace‑ Contact ƒ ment. Alternatively, you can use our download portal: www.vacuubrand.com You are welcome to contact us at any time in writing or by tele‑ ƒ phone if you would like more information, have questions about our products or wish to share feedback with us.
  • Page 7: Display Conventions

    Introduction 1.2.2 Display conventions Warning levels DANGER Display conventions Indicates an imminent hazardous situation. Disregarding the situation will result in serious and even fatal injury or death. Take appropriate action to avoid dangerous situa‑ > > tions! WARNING Indicates a potentially hazardous situation. Disregarding the situation could result in serious, even fatal injury or massive damage to property.
  • Page 8: Symbols And Icons

    Introduction 1.2.3 Symbols and icons This manual uses symbols and icons. Safety symbols indicate specific risks associated with handling the product. Symbols and icons are designed to help you identify risks more easily. Safety symbols Explanation of Hazardous substance ‑ General safety symbols hazards to human health.
  • Page 9: Handling Instructions (Action Steps)

    Introduction 1.2.4 Handling instructions (action steps) Instructions (single step) Display of operating steps > Perform the step described. 5 Result of action Instructions (multiple steps) 1. First step 2. Next step 5 Result of action Perform the steps in the order described. 1.2.5 Abbreviations abs.
  • Page 10: Term Definitions

    VACUU·SELECT controller and ® VACUU·SELECT Sensor. ® VACUU·BUS Bus system from VACUUBRAND for com‑ ® munication between peripheral devices with VACUU·BUS enabled gauges and control‑ ® lers. The maximum permissible cable length is 30 m.
  • Page 11: Safety Information

    Safety information Safety information The information in this chapter must be observed by everyone who works with the product described here. The safety instructions are valid for the complete life cycle of the product. 2.1 Usage Only use the product if it is in perfect working condition. 2.1.1 Intended use A diaphragm pump of the Mx 1x VARIO select...
  • Page 12: Improper Use

    Safety information 2.1.2 Improper use Incorrect use or any application which does not correspond to the Improper use technical data may result in injury or damage to property. Improper use includes: using the product contrary to its intended use, ƒ using the product in non‑commercial environments, unless the ƒ...
  • Page 13: Obligations

    Safety information pumping oxidizing and pyrophoric substances, liquids or solids, Foreseeable misuse ƒ pumping hot, unstable, or explosive media, ƒ pumping substances which may react explosively under impact ƒ and/or elevated temperature without an air supply. No foreign bodies, hot gases or flames from the application IMPORTANT! must be allowed to enter the equipment.
  • Page 14: Target Group Description

    Responsibility matrix Responsibility Responsible Task (Job) Operator Specialist Assignment Matrix specialist Installation Initial use Network integration Operation Error report Remedy Maintenance Repair Repair order Cleaning, simple Shutdown Decontamination see also website: VACUUBRAND > Support > Instructions for repair Alternatively, arrange for decontamination by a qualified service provider 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 15: General Safety Information

    Safety information 2.4 General safety information Products from VACUUBRAND GMBH + CO KG are subject Quality standards to stringent quality testing with regard to safety and operation. safety Each product undergoes a comprehensive test program prior to delivery. 2.4.1 Protective clothing...
  • Page 16: Laboratory And Working Materials

    Safety information 2.4.3 Laboratory and working materials DANGER Hazardous substances could be discharged at the outlet. During aspiration, hazardous, toxic substances at the outlet can get into the ambient air. Observe the national regulations for safe handling of > > hazardous substances.
  • Page 17: Eliminate Sources Of Danger

    Safety information 2.4.4 Eliminate sources of danger Take mechanical stability into account The high compression ratio of the pump may result in a higher Note mechanical load pressure at the outlet than the mechanical stability of the system capacity allows. >...
  • Page 18 Safety information Prevent foreign bodies inside the pump Particles, liquids and dust must not get inside the vacuum pump. Observe vacuum pump dimensioning > Do not pump any substances which could form deposits inside the vacuum pump. > Install suitable separators and/or filters upstream of the inlet. Suitable filters are chemically resistant, clog‑proof and have a reliable flow rate, for example.
  • Page 19 Safety information Risk of burns due to hot surfaces or overheating The surface of the vacuum pump can reach operating tempera‑ Surface tempera‑ tures > 70 °C, in particular when pumping heated media. The sur‑ tures face temperature of the silencer in particular might be elevated in case of high gas flow.
  • Page 20: Motor Protection

    Safety information Keep signs legible Keep labels and information symbols and warning labels always Signs and labels in a well readable condition: > Connection labels > Warning signs and notice labels > Motor data and rating plates 2.5 Motor protection The pump motor has a temperature sensor on the circuit board as Overheating protection, blockage...
  • Page 21: Atex Equipment Category

    > If necessary vent with inert gas. Information on the ATEX equipment category is also available on our website at: www.vacuubrand.com/.../Information‑ATEX 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 22: Proper Disposal

    Safety information 2.7 Proper disposal Notice Risk of environmental damage due to incorrect disposal of the product. Do not dispose your product in household waste! > > Electronic components are subject to hazardous waste treat‑ ment and must only be disposed of by certified specialists. Observe the national regulations for safe disposal and envi‑...
  • Page 23: Product Description

    Product description Product description The diaphragm pumps described essentially consist of a diaphragm pump with VARIO drive, a VACUU·SELECT vacuum ® ® controller and a VACUU·SELECT Sensor ® 3.1 Schematic design Side and front view Meaning VACUU·SELECT Sensor, to be mounted externally on suction ®...
  • Page 24: Diaphragm Pump Series

    The diaphragm pumps differ in the internal connection of the pump heads. Diaphragm pumps Mx 1x VARIO select Diaphragm pump Pump heads Stages Stages of diaphragm pump ME 16 VARIO select MD 12 VARIO select MV 10 VARIO select 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 25: Installation And Connection

    Installation and connection Installation and connection 4.1 Transport Products from VACUUBRAND are packed in sturdy, recyclable packaging. The original packaging is accurately matched to your product for safe transport. If possible, please keep the original packaging, e. g., for >...
  • Page 26: Installation

    Installation and connection  Example Lift out the diaphragm pump > Please note that a dia‑ phragm pump can weigh approx. 28 kg. We recom‑ mend using a lifting aid. > Lift the device out of the packaging by the side han‑ dles.
  • Page 27 Installation and connection Installing the vacuum pump > Place the vacuum pump on a stable, non‑vibrating, level sur‑ face.  Example 5 cm Sketch of minimum distances in laboratory furniture 5 cm 5 cm > When installing in lab furniture, maintain a minimum distance IMPORTANT! of 5 cm (2 in.) to adjacent objects or surfaces.
  • Page 28: Controller Base

    Installation and connection 4.3 Controller base The base, controller, screw fittings and vacuum sensor are en‑ closed separately. Before installation, the base can be mounted on the pump and the controller clipped into place. Alternatively, the controller can be clipped into a recess in the lab furniture or used as a freestanding unit (unfold the stand).
  • Page 29: Connection

    Installation and connection 4.4 Connection The diaphragm pumps have a vacuum connection and an outlet connection. Connect your diaphragm pump as described in the examples below. 4.4.1 Assemble silencer (EX) As standard the diaphragm pumps are equipped with a silencer at Silencer at the outlet EX the outlet (EX).
  • Page 30: Vacuum Connection (In)

    Installation and connection Assemble the silencer Assemble silencer > Unpack the silencer and screw it in the thread at the outlet of the pump. 5 Silencer assembled. 4.4.2 Vacuum connection (IN) CAUTION Flexible vacuum hoses can contract during evacuation. Connected components that are not secured can cause injury or damage due to jerky movement (shrinkage) of the flexible vacuum hose.
  • Page 31 Installation and connection IMPORTANT! > Use a sufficiently stable vacuum hose that is designed for the required vacuum range. > Keep hose lines as short as possible. > Connect hose lines in a gas‑tight manner to the vacuum pump. > Avoid kinks in the vacuum hose. Connect the vacuum hose ...
  • Page 32: Outlet Connection (Ex)

    Installation and connection 4.4.3 Outlet connection (EX) As standard the diaphragm pumps are equipped with a si‑ lencer at the outlet (EX). The screwed in silencer can be re‑ placed optionally by a small flange connection KF DN 16 or a hose nozzle DN 15 mm as outlet connections ...
  • Page 33 Installation and connection Connect the exhaust gas hose (optional) Connect the exhaust gas hose to the pump, either via the small flange connection KF DN 16 or via the hose nozzle DN 15 mm. The following example describes the connection via hose nozzle. ...
  • Page 34: Connect Venting Valve (Optional)

    Installation and connection 4.4.4 Connect venting valve (optional) DANGER Risk of explosion due to venting with air. Depending on the application, venting can cause explo‑ sive mixtures to form or other hazardous situations to arise. Never vent processes with air which could form an >...
  • Page 35: Electrical Connection

    Installation and connection 4.4.5 Electrical connection Electrical connection of the pump  Example Electrical connection diaphragm pump 1. Plug the connector (e) on the power cable into the power con‑ nection of the vacuum pump. 2. Plug power plug (f) into the power outlet. 5 Vacuum pump electrically connected.
  • Page 36 Installation and connection IMPORTANT! > Use the power plug which fits your power supply. > Do not use multiple sockets connected in series as the power connection. 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 37: Commissioning (Operation)

    Commissioning (operation) Commissioning (operation) 5.1 Switch on Switch pump on Switch pump on 1. Switch rocker switch (a) on – switch position I. 2. Press ON/OFF button (b) on the controller. 5 The start screen is displayed. 5 After approx. 30 seconds, the process screen appears with the operating elements in the controller display.
  • Page 38 Commissioning (operation) Process screen Process screen vacuum controller Status bar Analogue pressure display – pressure curve Digital pressure reading – pressure value (target value, actual value, pressure unit) Process screen with context features Screen navigation Operating elements for control Operating elements Button Vacuum controller Function...
  • Page 39: Operation ( See Description Of Controller)

    Commissioning (operation) 5.2.1 Operation ( see description of controller) Start the vacuum controller Start Stop the vacuum controller Stop Venting (option) Venting 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 40: Shutdown (Switch Off)

    Commissioning (operation) 5.3 Shutdown (switch off) Take the pump out of operation 1. Stop the process. Switch pump off 2. Disconnect the pump from the apparatus. 3. Let the vacuum pump run on for about 30 minutes, with open inlet. 5 Condensate and media residues will be flushed out of the vacuum pump.
  • Page 41: Storage

    Commissioning (operation) 5.4 Storage Store the vacuum pump 1. Clean the vacuum pump if dirty. 2. Recommendation: Perform a preventive maintenance before storing the vacuum pump. This is especially important if it ran more than 15,000 operating hours. 3. Close the suction and outlet lines, e.g., with the transport caps.
  • Page 42 Commissioning (operation) 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 43: Troubleshooting

    VACUU·BUS plug‑in in connection and measured val‑ connection or cables cables to the con‑ defective or not con‑ troller. nected. Specialist Sensor defective. Replace defective components. 1 -> Phone: +49 9342 808-5660, fax: +49 9342 808-5555, service@vacuubrand. 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 44 Troubleshooting Error – Cause – Error ` Possible cause Personnel 3Remedy Remedy Specialist Venting valve No voltage applied. Check VACUU·BUS plug‑ (optional) does VACUU·BUS plug‑in in connection and not switch connection or cables cables to the con‑ defective or not con‑ troller.
  • Page 45 Troubleshooting Error – Cause – Error ` Possible cause Personnel 3Remedy Remedy Operator No or very little Leak in the suction Check suction line line or in the appara‑ and apparatus for suction power tus. leaks. Operator Vacuum line too long Use a shorter vac‑...
  • Page 46 Troubleshooting Error ` Possible cause Personnel 3Remedy Operator Loud operating No silencer or hose Check silencer or hose and install noises mounted at the outlet. correctly. Outlet line open. Check outlet line connections. Connect the out‑ let line to an extrac‑ tion system or fume hood.
  • Page 47: Cleaning And Maintenance

    Cleaning and maintenance Cleaning and maintenance WARNING Danger due to electrical voltage. Switch the device off before cleaning or maintenance > > work. Unplug the power plug from the socket. > > Risk from contaminated parts. Pumping hazardous media can result in hazardous substances adhering to internal parts of the pump.
  • Page 48: Information On Service Work

    Cleaning and maintenance 7.1 Information on service work Recommended maintenance intervals Maintenance intervals* if required 15000 h Replace diaphragms Replace valves Replace O‑rings Clean or replace molded PTFE‑hose Clean the vacuum pump * Recommended maintenance interval after hours of operation and under nor- mal operating conditions;...
  • Page 49 Cleaning and maintenance Tools needed for maintenance  Example Tool Tool Size Service kit Service kit MD 12 / MV 10 VARIO select #20696827 Service kit ME 16 VARIO select #20696819 Diaphragm wrench #20636554 SW66 Flat nose pliers Close hose clamps Flat‑head screwdriver Open hose clamps Size 1...
  • Page 50: Cleaning

    Cleaning and maintenance 7.2 Cleaning IMPORTANT! This chapter does not contain descriptions for decontamina‑ tion of the product. This chapter describes simple measures for cleaning and care. > Before cleaning, switch off the diaphragm pump. 7.2.1 Diaphragm pump Clean the surfaces Clean dirty surfaces with a clean, slightly damp cloth.
  • Page 51: Diaphragm Pump Maintenance

    Cleaning and maintenance 7.3 Diaphragm pump maintenance 7.3.1 Maintenance items Servicing positions  Example Diaphragm pump, front, semi‑transparent view Maintenance items and sequence Meaning Bottom pump head pair Top pump head pair Right pump head pair Left pump head pair Suction/pressure distributor (only MV 10 / MD 12) Straightforward maintenance due to split work steps.
  • Page 52: Preparation

    Cleaning and maintenance 7.3.2 Preparation Disassemble the controller and base  see also chapter: 4.3 Controller base on page 28 Disassemble the device and housing sections Disassemble the front housing section 1. Switch the diaphragm pump off 2. Unscrew the silencer from the and unplug the power plug.
  • Page 53 Cleaning and maintenance 5. Unscrew the 4 screws from the 6. Remove the housing section rear housing section; hex key and set it aside. size 4. Remove the side panel 1. Unscrew the 2 outer screws 2. Unscrew the right screw from from the side panel retain‑...
  • Page 54 Cleaning and maintenance 5. Lift the left side panel off the 6. Unscrew the screw fittings from pump. Place the pump care‑ the side panel; hex key size 5. fully on its other side. Remove the right side panel 7. Lift the right side panel off the pump.
  • Page 55: Replacing The Diaphragms And Valves

    Cleaning and maintenance 7.3.3 Replacing the diaphragms and valves Exploded drawing of pump head (example) Exploded‑drawing pump head Valve maintenance Housing cover Valves O‑rings size 28 x 1,5 Diaphragm maintenance Head cover Diaphragm clamping disc with square‑head screw Double diaphragm, 2 diaphragms per pump head Diaphragm support disc Spacer discs, max.
  • Page 56 Cleaning and maintenance Bottom pump head pair  Example Bottom pump head pair 1. Turn the pump to bring the bot‑ 2. Pull off the molded hoses. tom pump head pair to the top. Open the hose clips on the hoses.
  • Page 57 Cleaning and maintenance Remove valves and O‑rings 6. Carefully remove the used 7. Carefully remove the used valves. O‑rings. 8. Remove the head covers. Check the surfaces for dirt. Clean dirty surfaces carefully. 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 58 Cleaning and maintenance Replace the diaphragms  Example Replacing the diaphragms 1. Lift the diaphragm upwards on 2. Carefully position the dia‑ either side. phragm wrench on the dia‑ phragm support disc and unscrew the assembly with the diaphragm wrench attached. 3.
  • Page 59 Cleaning and maintenance  Example Replacing the diaphragms 5. Pull out the diaphragm clamp‑ 6. Place the new diaphragm over ing disc and remove the used the square head of the clamp‑ diaphragm. ing disc. IMPORTANT! > Double diaphragm comprising 2 single diaphragms. Use the dia‑ phragms only in pairs.
  • Page 60 Cleaning and maintenance 9. Hold the spacer discs firmly 10. Initially tighten the assembly and place all the components with the diaphragm wrench by carefully on the connecting hand. rod thread. 11. Then position a torque 12. Repeat steps 1‑11 for replac‑ wrench with socket head bit ing the next diaphragm.
  • Page 61 Cleaning and maintenance Insert valves  Example Insert valves and O‑rings 1. Place the head covers onto 2. Insert the new O‑rings into the the diaphragms. Pay attention grooves. to the correct orientation of the Insert the new valves. Pay head covers.
  • Page 62 Cleaning and maintenance 7. Secure the hose clips on the 8. Turn the pump to bring the hose nozzles, e.g., with flat nose top pump head pair to the top. pliers. Support the pump, e. g., with rigid foam. Maintain the top, >...
  • Page 63 Cleaning and maintenance Assemble the device and housing sections Mount the side panel 1. Place the side panel on the 2. Wind the screw fittings into the pump. side panel; hex key size 5. 3. Turn the pump to the top. 4.
  • Page 64 Cleaning and maintenance 7. Wind in the screw of the side 8. Place the rear housing section. panel retaining plate at the rear; hex key size 4. 9. Wind in the screws of the housing section; hex key size 4. >...
  • Page 65 Cleaning and maintenance Suction/pressure distributor maintenance Maintenance of This description only applies to diaphragm pumps MD 12 suction/pressure and MV 10 VARIO select. distributor Exploded drawing of suction/pressure distributor (example)  Example Pressure relief valve Maintenance overpressure relief valve + O‑ring 1 Countersunk screw M4x80 2 Connection DN 25 3 Hose nozzle...
  • Page 66 Cleaning and maintenance Replace pressure relief valve + O‑ring Replace pressure relief valve and O‑ring 1. Place the vacuum pump on 2. Only open the hose clips above a clean, stable surface as the pressure distributor; flat‑ shown. head screwdriver size 1. 3.
  • Page 67 Cleaning and maintenance 7. Carefully remove the used 8. Clean the pressure distributor if pressure relief valve and the necessary. O‑ring, e. g., with a narrow flat‑ head screwdriver. Bottom 9. Place the new pressure relief 10. Place the suction distributor valve on the clean surface.
  • Page 68 Cleaning and maintenance 13. Push the molded hoses back 14. Secure the hose clips on the into place on the hose noz‑ hose nozzles, e.g., with flat zles. nose pliers. Assemble the device and housing sections Assemble the device and housing sections 1.
  • Page 69 Cleaning and maintenance 5. Screw the silencer in the 6. Secure the controller on the thread at the outlet.. diaphragm pump and connect all cables. 7. Plug in the power plug. If maintenance work has been completed in full: > Connect the hoses for operation. >...
  • Page 70: Appendix

    Appendix Appendix 8.1 Technical information Diaphragm pump series ME 16 VARIO select MD 12 VARIO select MV 10 VARIO select 8.1.1 Technical data Technical data Ambient conditions (US) Ambient temperature, max. 10–40 °C 50–104°F Working temperature 10–40 °C 50–104°F Storage/transport temperature ‑10–60 °C...
  • Page 71 ME 16 VARIO select Max. pumping speed 20 m 11.8 cfm Ultimate vacuum, abs. 70 mbar 53 Torr Number of cylinders/stages MD 12 VARIO select Max. pumping speed 16 m 9.4 cfm Ultimate vacuum, abs. 1,5 mbar 1.1 Torr Number of cylinders/stages MV 10 VARIO select Max.
  • Page 72 552 mm x 260 mm 21.7 in x 10.2 in x 17.7 in x 450 mm Weight* 28,3 kg 62.4 lb MD 12 VARIO select 552 mm x 260 mm 21.7 in x 10.2 in x 17.7 in x 450 mm Weight* 28,3 kg 62.4 lb...
  • Page 73: Wetted Materials

    Appendix 8.1.2 Wetted materials Component Wetted materials Pump Wetted materials Housing cover Aluminium alloy Head cover Aluminium alloy (AlSi12) Diaphragm clamping disc Aluminium alloy (AlSi12) Diaphragm Valves O‑rings Small flange Stainless steel Hose fittings ETFE/ECTFE Hoses PTFE Inlet Aluminium alloy Suction/pressure distributor Aluminium alloy Outlet...
  • Page 74: Rating Plate

    Appendix 8.1.3 Rating plate Data on rating plate In the event of an error, make a note of the type and serial > > number on the rating plate. When contacting our Service Department, please provide > > the type and serial number from the rating plate. This will allow us to provide you with specific support and advice for your device.
  • Page 75: Ordering Information

    Ordering information Diaphragm pump series Order no. pump series ME 16 VARIO select 207411xx MD 12 VARIO select 207431xx MV 10 VARIO select 207441xx * Order no. depends on power cable CEE, CH, UK, US, CN, IN Accessories Ordering information Order no.
  • Page 76  VACUUBRAND > Support > Repair instructions > Diaphragm pumps. Sources of supply Purchase original accessories and original spare parts from a subsidiary of VACUUBRAND GMBH + CO KG or your local dis‑ tributor. International Information about our complete product range is available >...
  • Page 77: Service

    Appendix 8.3 Service Take advantage of the comprehensive range of services Service offer and service range available from VACUUBRAND GMBH + CO KG. Services in detail Product consultation and practical solutions ƒ Fast delivery of spare parts and accessories ƒ...
  • Page 78: Index

    Appendix 8.4 Index Index Abbreviations ....9 Maintain minimum distance ..19 Accessories ....75 Maintain the top, right and left Action steps .
  • Page 79 Appendix Index Responsibility matrix and areas of competence ... . 14 Return (reshipment) ... . . 77 Return to use after maintenance . . . 69 Safety information .
  • Page 80: Ec Declaration Of Conformity

    (ATEX‑RL), 2011/65/EU (RoHS‑2) Membranpumpen / Diaphragm pumps / Pompes à membrane Typ / Type / Type: ME 16 VARIO select, MD 12 VARIO select, MV 10 VARIO select Artikelnummer / Order number / Numéro d‘article: 20741150, 20743150, 20744150 Seriennummer / Serial number / Numéro de série: Siehe Typenschild / See rating plate / Voir plaque signalétique...
  • Page 81: En_Mx10+12+16_Vario_Vsel_V1.0

    20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 82 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 83 20901121_EN_Mx10+12+16_VARIO_Vsel_V1.0_020818...
  • Page 84 Technology for Vacuum Systems Manufacturer: VACUUBRAND GMBH + CO KG Alfred‑Zippe‑Str. 4 97877 Wertheim GERMANY Phone: ƒ Head office +49 9342 808‑0 ƒ Sales +49 9342 808‑5550 ƒ Service +49 9342 808‑5660 Fax: +49 9342 808‑5555 Email: info@vacuubrand.com Web: www.vacuubrand.com...

This manual is also suitable for:

Mv 10 vario selectMe 16 vario select

Table of Contents