MP (Multi Pulse) and HE (High Energy) specify the method to apply the energy to the print head.
For the Multi Pulse method, the energy table is specified by "Table", and strobe duty is specified by
"Duty", respectively.
MP
HE
0
0
Single pulse, Normal energy
0
1
Single pulse, High energy
1
X
Multi pulse
•
Set the tear-off delay time in units of msec.
•
Option usage
15
14
13
12
11
Reserved
•
Conversion from metric to inch for the print speed and feed speed
Ips = (n+1) x 0.25
•
The "TAP" and "STK" are not applicable to the B-SX600.
Print energy apply method
10
9
8
7
TAP
Rsv
STK
6
5
4
3
2
1
Reserved
- 10 -
B-SX600 Command Manual
0