4.4.

Connections using RS485

Convexs/Invexs connected to Nedap AEpacks using RS485: For those
AEpacks not having RS485 on board use the additional AX1012 (RS485
to RS232 converter)
Convexs / Invexs
A1
1
Power / XSMOD
A2
2
POWER GND/shield
A3
3
A (-)
A4
4
B (+)
A5
5
D0
A6
6
D1
A7
7
BEEP
A8
8
UL*
A9
9
GND
A10
10
NA*
Remarks:
1 On AP1003 the RS485 is available on Upper Row connector points 13 - 16, only from PMS D or higher
2 For AP1003 with PMS below D use the additional AX1012 to convert RS232 from AP1003 to RS485 for
Convexs
3 Power for Convexs can be supplied by
-
External Power Supply
-
AEpack, check correct voltage and current at given AEpack output
4 Beeper on Convexs can be optional controlled
-
on AP6003 this can be done by pin 16
-
on other AEpacks use Relais output
5 LED control is supplied over the RS485 communication, so no additional wiring is needed
6 Cable shield must be connected to Power GND of Convexs (A2) and GND of external device or metal
case of the external device (at housing of AP6003, AP4x03x, AEbox)
7 If Convexs replaces e.g. DC130 antenna the existing cabling of the DC130 antenna (4 x 0,25qmm) can be
reused for RS485 and Power only if cable length not exeeds 50 meters and cable shield is correct
connected.
8 PIN code for the Invexs reader is transmitted using the RS485 communication.
4.5.

Connections using RF output

Convexs / Invexs
A1
1
Power / XSMOD
A2
2
POWER GND/shield
A3
3
A (-)
A4
4
B (+)
A5
5
A6
6
A7
7
BEEP
A8
8
UL*
A9
9
GND
A10
10
NA*
Remarks:
1 For Nedap reader AEpacks the AX1014 must be applied to
each AEpack
2 For the Accessor III / SimpleXS / AC3/2TR the AB350 must be applied
3 Existing cabling can be re-used when the Nedap antenna is replaced by the Convexs
4 Power is supplied to the Convexs by the RF signals on A1 and A2, no additional Power Supply is needed.
5 Beeper can be controlled optional by making the correct configuration settings or hardware connection.
6 Cable shield must be connected to Power GND of Convexs (A2) and GND of external device or metal
case of the external device (at housing of Accessor, AP4x01, AEbox)
7 PIN code for Invexs readers is NOT possible
8 Invexs 190 to AX1014 or AB350 needs additional connection between GND (for UL and NA) and
Antenna GND on the AX1014 / AB350 (Invexs 190 has no separate cable for this connection)
© Nedap N.V.
AP6003
AP4x03x
3)
Lower 1
14
8
10
4)
16
AX1014
11 – ANT
12 – GND
D0
D1
relay
13 – UL*
14 – GND
8
15 – NA*
Nedap Readers Installation Guide
1)
AP1003
3)
3)
Upper
1
1
14
Lower
1
8
Upper
13
10
Upper
16
--
--
--
--
--
--
--
--
--
--
--
--
AB350
ANT
1 2 3
4 5 6
7 8 9
C 0 E
GND
--
--
relay--
UL*
1 2 3
4 5 6
7 8 9
C 0 E
GND
NA*
1 2 3
4 5 6
7 8 9
C 0 E
2)
AP1003+AX1012
3)
Upper
1
Lower
1
AX1012
Rx+
AX1012
Rx-
--
--
--
--
--
--
AX1014
AX1014
AX1014
AX1014
AX1014
Accessor III /
SimpleXS
AC3/2TR
AB350
Page 14 of 21