5. - INSTALLATION REQUIREMENTS

THIS APPLIANCE MUST BE INSTALLED AND SERVICED BY A PROPERLY QUALIFIED, (IN ACCORDANCE WITH LOCAL &
NATIONAL CODES), INSTALLATION ENGINEER.
It is the Law in the UK that All gas appliances are installed by a competent person in accordance with the GAS SAFETY (INSTALLATION
AND USE) REGULATIONS 1998 (As amended), the relevant British Standards for Installation work, Building
Regulations, Codes of Practice and these Instructions. In the UK a Registered Installer is deemed competent. In the
Republic of Ireland, all Irish Standards, Local Codes and Bord Gais recommendations should be adhered to.
The Installation should also be carried out in accordance with the following where relevant:
1. BS5871 Part 2
2. BS5440 Parts 1 & 2
Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development
Department.
In the Republic of Ireland Installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of
Practice, these Manufacturers Instructions and any Rules In Force.
Particular Reference should be made to the Ventilation Requirements, for the UK this Appliance would not normally require any
additional purpose provided ventilation, for the Republic of Ireland ventilation should be in accordance with IS813 Domestic Gas
Installations.
Failure to comply with the above could leave the Installer Liable to Prosecution and Invalidate the Warranty.
IMPORTANT
BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY. THESE INSTRUCTIONS SHOULD
BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING. PRIOR TO INSTALLATION ENSURE THAT THE GAS

6. - APPLIANCE DATA

a. Gas Type: See Data Plate, (Natural Gas at 20mbar or Propane at 37mbar).
b. Burner Pressure: Natural Gas 18.7mbar cold
c. Control System: Manual or Thermatronic (Fully Sequential) Control System operated by Handset pointed at Receiver.
d. Fire Safety: Oxygen Depletion & Flame Failure Device.
e. Ignition: Manual-Integral Piezo Igniter, Thermatronic-Full Sequential Control.
f. Inlet Connection: 8mm Compression Fitting to Gas Isolation Elbow.
g. Category: I2H, I3P.
h. Injector: Natural Gas (G20) -360 Multi hole.
i. Heat Input: High: Natural Gas (G20) - 5.6kW
j. Heat Input: Low: Natural Gas (G20) - 2.0kW
k. Efficiency Class: 1. The Efficiency of this appliance has been measured as specified in BS7977-1:2009 and the results obtained
were 78.5% gross on Natural Gas and 74.3% gross on Propane. The test data has been certified by GL Industrial Services UK
Ltd (0087) and can be used in the UK Government's Standard Assessment Procedure (SAP) for Energy Rating of Dwellings.
l. Heat Output: High: Natural Gas (G20) - 4.4W
m. Heat Output: Low: Natural Gas (G20) - 1.3kW
n. Pilot ODS Type: Natural Gas (G20) - P448D 0608. Propane (G31) - P477 0906.

7. - APPLIANCE DIMENSIONS

With Flat Front
Solid lines denote 3 sided frame for fireplace use. Additional detail for "Hole in the Wall" frames is shown by dotted lines.
Designs may vary; the diagram above is to show important dimensions only .
3. BS6461 Parts 1 & 2
TYPE AND PRESSURE ARE AS STATED ON THE APPLIANCE DATA BADGE.
Propane 36.3mbar cold
Propane (G31) - 180 Single hole.
Propane (G31) - 5.25kW - gross figures quoted
Propane (G31) - 2.0kW - gross figures quoted
Propane (G31) - 3.9kW
Propane (G31) - 1.3kW
4. BS6891
5. BS8303
With Curved Front