Important Notes - Nu-Flame Vitesse H.E. Use, Installation & Servicing Instructions

Inset convection heater suitable for natural gas & propane
Table of Contents

Advertisement

1. - IMPORTANT NOTES

a. This appliance must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b. The connection of this appliance and ventilation requirements (if any) are to be according to National & Local Codes.
c. This appliance does not normally require any purpose provided additional ventilation, however if it has been found necessary to
add a vent periodically check that it is free from obstruction.
d. Consult all Instructions before Installation and Use.
e. Do not throw rubbish on, or attempt to burn any materials on this appliance. Any Debris or Foreign Matter must be removed from
the fire.
f. Under No Circumstances must this fire be used if the Glass Panel is broken, damaged, cracked or has been removed.
g. The glass panel and outer parts of this fire will become hot during use, cloths or combustible items must not be placed close to
or on the fire. We recommend that a Fireguard conforming to BS8423 should be used for protection of Young Children the
Elderly, Infirm and Pets.
h. The appliance should be Serviced Annually in accordance with the Gas Safety & Uses Regulations.
i. Where the flue has been used for Solid Fuel it must be swept before Installation.
j. If at any time you smell gas or fumes turn the fire off and contact your Installer.
k. These Instructions must be left with the User for future reference.
l. During its first period of use any protective coatings and oils will burn out of the appliance and it is wise to ventilate the room for
the first hour of use.
m. This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the fire if the
oxygen level in the room is depleted, due to lack of primary air, or obstructed flue (blocked chimney) that would lead to
incomplete combustion of the gas. It must not be tampered with and only replaced with a genuine Nu-Flame ODS.
n. In the event that the fire shuts down for any reason, attempt to restart it. If there is a continuing problem, call in a properly
qualified specialist engineer.
o. There are no user replaceable parts in the appliance apart from the batteries, if a High Level or Thermatronic Electronic Control
System was ordered.
p. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build up of soot. If there is, the appliance must be serviced.
q. Coal or Pebble fuel effects, manufactured from refractory fibre, are supplied with this appliance. Do not use real coals or pebbles
as this is dangerous. If the simulated fuel bed components need renewing please obtain suitable replacements from a Nu-Flame
Stockist.
r. The fire must be installed in accordance with the rules in force and these Instructions it must be installed into a fireplace or
builders opening as detailed in these Instructions.
s. No combustible materials e.g. curtains must be closer than 500mm to the fire.
t. For Fire Surround Applications a 150mm (6") combustible shelf can be fitted above the fire provided it is 195mm above the
Fireplace Opening.
u. The Fire can be installed into a suitably designed fire surround with a 150
v. Explain to the customer that over time some wall staining will occur above the fire and this is due primarily to particles of dust
present in the hot convection air circulating up and over the fire/surround and sticking to the wall.
! IMPORTANT NOTE ! THE GLASS PANEL ON THIS FIRE WILL BECOME VERY HOT DURING
OPERATION - SEE ITEM 'g.' ABOVE.
It is quite normal for the fire to make popping and burbling sounds when in use, as would a solid fuel fire.
THE VITESSE H.E.
USER INSTRUCTIONS
4
º
C Rating.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents