Nu-Flame N1 Use & Maintenance Instructions

Evolution plus gas effect fires (natural gas & lpg)

Advertisement

Unit 4, Kimpton Trade & Business Centre
Minden Road, Sutton, Surrey SM3 9PF
Tel: 020 8254 6802
USE & MAINTENANCE INSTRUCTIONS
FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES
NATURAL GAS MODELS: N1, N1I, N2R, N2, N2I, N3R, N3, N3I, N4R, N4, N4I, N5R, N5, N5I & N6
a. This fire must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b. The connection of this appliance, and ventilation requirements (if any) are to be according to National & Local Codes.
c. The chimney should be swept before the appliance is installed.
d. Open fires are a hazard; it is recommended that a guard be fitted to provide protection for children, the elderly or infirm. (See
National & Local Regulations if any.)
e. This appliance is intended for decorative purposes only.
f. Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign matter must be removed
from the fire.
g. The appliance should be serviced by a qualified gas fitter every 12 months.
FOR A FIRE WITH THERMATRONIC ELECTRONIC CONTROL SYSTEM SEE SEPARATE OPERATING INSTRUCTIONS
a. Turning pilot on from off position depress knob and turn anti-clockwise until it sparks.
More than one attempt may be required to light the pilot. Once lit hold in for about 10 seconds.
Release knob and turn to pilot position.
b. To turn burner on from pilot position depress knob and turn anti-clockwise to low flame.
To go to high flame depress knob again and turn anti-clockwise as far as it will go.
The flame can be varied to any point between high and low as desired.
c. To turn off depress knob and turn clockwise depressing knob at each point as you go
all the way round to off.
d. This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the main
burner if the oxygen level in the room is depleted, due to a lack of primary air, or obstructed flue that would lead to incomplete
combustion of the gas.
e. In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem call in a properly
qualified specialist engineer.
f. There are no user replaceable parts in this appliance.
g. Do not change the fire front or fret supplied without checking with the supplier of this unit. A minimum primary air
inlet area of 50 sq. cm is required for the safe and efficient operation of the fire. Failure to observe this instruction is
potentially dangerous and will possibly invalidate the guarantee.
h. Regularly inspect the purpose provided ventilator (if fitted) to check that it is free from any obstruction.
i. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build up of soot. If there is, the appliance must be cleaned.
a. Do not use a vacuum cleaner to clean the appliance as you will suck up the vermiculite.
b. Gently remove the simulated coal, pebbles, logs or driftwood one by one & remove soot deposits with a soft brush.
c. The vermiculite granules should be level with the top edge of the burner tray. Top up the vermiculite granules if required.
Ensure that vermiculite granules are not obstructing the burner slots or fouling the pilot burner assembly.
d. Coal, pebble, log & driftwood effect fires: Re-lay as shown on the relevant drawing. Do not add more simulated coals,
pebbles, logs or driftwood or change the firebed layout in anyway.
(NATURAL GAS & LPG)
FOR DECORATIVE PURPOSES ONLY
LPG MODELS: L1, L2R, L2, L3R, L3, L4R, L4 , L5 & L6
LIGHTING & CONTROLLING THE FIRE – MANUAL FIRE
IMPORTANT NOTES
CLEANING THE FIRE
®
Simulated coals, simulated pebbles, simulated logs,
simulated driftwood or crushed rock manufactured
from refractory fibre, are supplied with this appliance.
Do not use real coals, pebbles, logs or driftwood, as
this is dangerous. If the simulated coals, simulated
pebbles, simulated logs or simulated driftwood need
renewing please obtain suitable replacements from a
GENERAL
Page 1 of 10
IMPORTANT NOTE
Nu-Flame stockist.

Advertisement

Table of Contents
loading

Summary of Contents for Nu-Flame N1

  • Page 1 (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY NATURAL GAS MODELS: N1, N1I, N2R, N2, N2I, N3R, N3, N3I, N4R, N4, N4I, N5R, N5, N5I & N6 LPG MODELS: L1, L2R, L2, L3R, L3, L4R, L4 , L5 & L6 GENERAL a.
  • Page 2: Installation & Servicing Instructions

    (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY NATURAL GAS MODELS: N1, N1I, N2R, N2, N2I, N3R, N3, N3I, N4R, N4, N4I, N5R, N5, N5I & N6 LPG MODELS: L1, L2R, L2, L3R, L3, L4R, L4, L5 & L6 THIS APPLIANCE MUST BE INSTALLED & SERVICED BY A PROPERLY QUALIFIED (IN ACCORDANCE WITH LOCAL &...
  • Page 3 INSTALLATION & SERVICING INSTRUCTIONS continued) Natural Gas Models (For G20 Gas) kW Input Net Burner Pressure Burner Model Flue Classes Category Injector Size (High Flame) (High Flame) Classes 1 & 2 16.8 mbar Class 1 Only 15 mbar Classes 1 & 2 18.1 mbar N2R Fireboxx350 Classes 1 &...
  • Page 4: Appliance Location

    INSTALLATION & SERVICING INSTRUCTIONS continued) APPLIANCE LOCATION a. This appliance must be hearth mounted in a builders opening or under an associated independent canopy or a fireplace recess. b. On NO ACCOUNT must this appliance be sited on combustible materials or carpets. It is not suitable for combustible walls. c.
  • Page 5 The burner tray is supplied with the Stainless steel burner block fitted in place c/w a 10mm ceramic fibre decorative insulation pad black side uppermost. This is simply placed on top and spares can be purchased from Nu-Flame. Fill the tray with vermiculite making sure the underside off the burner block is filled.
  • Page 6: Layout For Simulated Coals

    INSTALLATION & SERVICING INSTRUCTIONS continued) LAYOUT FOR SIMULATED COALS Due to the many pan sizes and shapes there is not an exact pattern and these coal layouts are intended as a guide to illustrate the general principles. It is important to leave spaces of 15mm - 20mm between the simulated coals to ensure good secondary aeration.
  • Page 7 INSTALLATION & SERVICING INSTRUCTIONS continued) LAYOUT FOR SIMULATED PEBBLES Due to the many pan sizes and shapes there is not an exact pattern and these layouts are intended as a guide to illustrate the general principles. On the base and second layer it is important to leave spaces of at least 10mm between the simulated pebbles to ensure good secondary aeration.
  • Page 8: Important Notes

    INSTALLATION & SERVICING INSTRUCTIONS continued) LAYOUT FOR SIMULATED LOGS / DRIFTWOOD Due to the many pan sizes and shapes there is not an exact pattern and these layouts are intended as a guide to illustrate the general principles. Do not overload the fire as it will spoil the appearance of the fire and cause sooting.
  • Page 9 INSTALLATION & SERVICING INSTRUCTIONS continued) COMMISSIONING THE FIRE a. Close all doors and windows, check operation of controls and burn for 5 minutes. Test for spillage of the flue products using a smoke match. Pass the lighted match along the top front edge, just inside the fire opening. If there is a small amount of spillage, run the fire for a further 10 minutes and re-test for spillage.