Procedure To Remove Four Way Valve And Coil - Daikin R71KV1 Service Manual

3 hp class removal procedure. outdoor unit, non-inverter, multi type.

Advertisement

Si211311E

6. Procedure to Remove Four Way Valve and Coil

Procedure
Step
∗ Make sure the refrigerant is
completely empty.
1
Remove the external
casing, etc., and
electrical parts
according to their
removal procedures.
2
Remove the four way
valve.
Heart the brazed parts
3
of the four way valve,
and remove the
assembly from the
piping side by drawing
out with a pair of pliers,
etc.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Procedure to Remove Four Way Valve and Coil
Note:
Apply the flame while cooling
with a leak cloth so that the
temperature of the main body
does not rise above 120 ºC.
Note:
When installing, first braze weld
the four way valve and attached
piping, then install the valve.
Be sure to check the position
angle of the piping when
brazing.
Points
9