Operation Details; Heating Operation - Panasonic CS-A18DKD Service Manual

Table of Contents

Advertisement

8 Operation Details

8.1.

Heating Operation

• Heating operation can be set using remote control.
• This operation is applied to warm the room temperature reaches the setting temperature set on the remote control.
• The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
to 30°C.
• During Heating operation, the compressor will stop running and restart as shown in below figure.
8.1.1.
Heating Operation Time Diagram
15
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-a18dkdCs-a24dkdCu-a24dkd

Table of Contents