8. Push up the Evaporator and pull out the Cross Flow Fan
from shaft. By then, Fan Motor can be taken out. (Fig. 9)
REMINDER - To reinstall the Fan Motor, put it back in
place, adjust the position of the Fan Motor's leadwire
appropriately as shown in the Fig. 7--- before installing the
Cross Flow Fan.

12.3. Remote Control Reset

When the batteries are inserted for the first time or the batteries
are replaced, all the indications will blink and the remote control
might not work.
If this happen, remove the cover of the remote control and you
will find a resetting terminal, and by shorting it with a minus
screwdriver, it will return to normal.