Huawei CX600-X1-M Series Hardware Description page 48

Metro services platform
Table of Contents

Advertisement

HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description
Item
Ambient
operating
temperature
Storage temperature
Ambient
operating
relative
humidity
Storage relative humidity
Long-term working altitude
Storage altitude
NOTE
In the dimensions shown in the table, the width (W) does not include the rack-mounting ears.
Temperature and humidity are measured at 1.5 m (4.92 ft.) above the floor and 0.4 m (1.31 ft.) in front of the
cabinet. There should be no protection board on the front or back of the cabinet.
"Short-term" refers to continuous working time that does not exceed 96 hours and accumulated working time
per year that does not exceed 15 days. If the working time exceeds either of these values, it is considered "long-
term".
Product Specifications
Table 2-5 System configuration list of the CX600-X2-M8
Item
Processing unit
SDRAM
Flash
eUSB
Issue 03 (2014-04-30)
Specification
MTTR
0.5
(hour)
Long-term
Standard mode: 0°C to +45°C (32°F to 113°F)
Short-term
-5°C to +55°C (23°F to 131°F)
(Short-term refers to a period of 96 consecutive hours or less
and a total of 15 days or less in a year.)
Remarks
Temperature change rate limit: 30°C/hour (86°F/hour)
-40°C to +70°C (-40°F to 158°F)
Long-term
5% RH to 85% RH, noncondensing
Short-term
5% RH to 95% RH, noncondensing
0% RH to 95% RH, noncondensing
Lower than 3000 m (9842.4 ft)
Lower than 5000 m (16404 ft)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 CX600-X2-M8 Hardware Description
Description
Main frequency: 1.2 GHz
2 GB
16 MB
2 GB
38