Typical Uses Of Multi-Function (M) Pin - Power integrations TOPSwitch-HX Series Manual

Enhanced ecosmart, integrated off-line switcher with advanced feature set and extended power range
Table of Contents

Advertisement

TOP252-262
Typical Uses of VOLTAGE MONITOR (V) and EXTERNAL CURRENT LIMIT (X) Pins (cont.)
+
DC
D
Input
Voltage
TOP259-261YN would
S
use the G pin as the
return for Q
.
R
-
Figure 26. Active-on Remote ON/OFF with Line-Sense and External
Current Limit.

Typical Uses of MULTI-FUNCTION (M) Pin

+
DC
Input
Voltage
D
S
-
Figure 29. Three Terminal Operation (MULTI-FUNCTION Features Disabled).
18
Rev. J 08/16
V
= I
× R
+ V
(I
UV
UV
LS
V
V
= I
× R
+ V
(I
OV
OV
LS
V
DC
@100 VDC = 76%
4 MΩ
R
MAX
LS
DC
@375 VDC = 41%
MAX
Q
can be an optocoupler
R
output or can be replaced
V
by a manual switch.
CONTROL
C
For R
=
12 kΩ
IL
I
= 61%
LIMIT
X
R
IL
Q
ON/OFF
R
16 kΩ
PI-4725-011008
+
DC
Input
Voltage
10 kΩ
Reset
Q
R
-
Figure 28. Line-Sensing for Undervoltage, Overvoltage, Line Feed-Forward and
Latched Output Overvoltage Protection with Device Reset.
D
C
M
S
S
S
S
M
D
CONTROL
C
PI-4727-061207
= I
)
+
V
UV
= I
)
V
oV
DC
Input
Voltage
TOP259-261YN would
use the G pin as the
return for R
.
IL
-
Figure 27. Line Sensing and Externally Set Current Limit.
V
= I
× R
+ V
UV
UV
LS
V
= I
× R
+ V
OV
OV
LS
For R
= 4 MΩ
LS
V
= 102.8 VDC
R
4 MΩ
UV
LS
V
= 451 VDC
OV
Sense Output Voltage
DC
@ 100 VDC = 76%
MAX
DC
@ 375 VDC = 41%
MAX
D
V
CONTROL
C
S
PI-4756-121007
+
DC
Input
Voltage
S C
-
Figure 30. Line Sensing for Undervoltage, Overvoltage and Line Feed-Forward.
V
= I
x R
UV
UV
V
= I
x R
OV
OV
For R
= 4 MΩ
LS
4 MΩ
R
LS
V
= 102.8 VDC
UV
V
= 451 VDC
OV
DC
@ 100 VDC = 76%
MAX
D
V
DC
@ 375 VDC = 41%
MAX
CONTROL
C
For R
IL
I
S
X
LIMIT
See Figure 55b for
R
other resistor values
IL
12 kΩ
(R
) to select different
IL
I
values.
LIMIT
(I
= I
)
V
V
UV
(I
= I
)
V
V
OV
V
= I
× R
UV
UV
V
= I
× R
OV
OV
For R
= 4 MΩ
LS
V
= 102.8 VDC
R
4 MΩ
UV
LS
V
= 451 VDC
OV
DC
@ 100 VDC = 76%
MAX
DC
@ 375 VDC = 41%
MAX
D
M
CONTROL
C
S
+ V
(I
= I
)
LS
V
V
UV
+ V
(I
= I
)
LS
V
V
oV
= 12 kΩ
= 61%
+ V
(I
= I
)
LS
M
M
UV
+ V
(I
= I
)
LS
M
M
OV
PI-4728-120307
www.power.com

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TOPSwitch-HX Series and is the answer not in the manual?

Table of Contents