INTRODUCTION
The Binks Models 84-598 and 84-599 Remote Fluid
Pressure Regulators are designed for use with Manual or
Automatic Spraying Systems utilizing an I/P (current to
pressure) or E/P (voltage to pressure) Transducer and where
precise fluid pressure outputs to spray gun are required.
The flow rate for model 84-598 is rated at 30 oz./min.
The flow rate for model 84-599 is rated at 100 oz./min.
ADVANTAGES
1. Accurate and repeatable fluid flows with maximum
control sensitivity.
2. Small plastic fluid cavity for rapid cleanout and color
flush cycles.
3. Positive spring-loaded shut-off (no leakage).
4. Designed to protect electronic transducer control systems
(independent vented air chamber).
5. Can be used on open and closed loop fluid pressure
control systems.
6. Maximum corrosion and solvent resistance.
7. Contains air gap to permit indication of air or fluid
diaphragm failure.
8. Contains carbide seats and valves.
SET-UP INSTRUCTIONS
The fluid inlet is fitted into the regulator body with a 3/8"
NPT(m) (standard), 3/8" NPS(m) (optional) swivel nut
connection. The fluid outlet connection is 3/8" NPS(m).
The control air inlet is 1/8" NPT(f).
The regulator may be mounted in either a horizontal or
vertical position. As little as 4 PSI control air pressure will
open this regulator depending on fluid pressure supply.
PRESSURE AND FLOW DATA
Regulation Range (Control Air) 4-100 psi 7.03 kg/cm
Maximum Fluid Inlet Pressure
Control Ratio (approx.)
Binks Models 84-598 & 84-599
REMOTE FLUID PRESSURE
REGULATORS
(30oz. / min. & 100oz. / min.)
CONTROL
AIR INLET
1/8" NPT(f)
2
200 psi
14.06 kg/cm
2
1:1
REGULATED
FLUID OUTLET
3/8" NPS (m)
DIMENSIONS
4-1/4"
3-1/2"
APPROX.
APPROX. WT. 1.85 LBS.
Replaces
Part Sheet
77-2871
UNREGULATED
FLUID INLET
3/8" NPT(m)
(STANDARD)
3/8" NPS(m)
(OPTIONAL)
13/16"
Part
Sheet
77-2871