4
C. Cables & hoses, etc.
Power cables
Air hoses
Overflow jar
RTD sensor
Miscellaneous accessories
The Bath Vessel Housing also contains the thermoelectric modules,
finned heat sinks, fans, and fluorescent lamps with ballasts. The rear
panel has two power connectors from the Lower Control Chassis, two air
pump connectors from the Control Chassis, and the bath fluid overflow
jar along with integral pump and tubing connections.
The TE-3000 system includes several cables, hoses, and accessories
which are necessary for operation of the system.
1.) Two large diameter power cables (AC and DC) with circular connec-
tors on their ends are provided to take power from the lower Control
Chassis up to the upper Bath Vessel Housing. The sex and type of
these connectors constrain their use in only one way - the proper
configuration.
2.) Two small diameter silicon air hoses (tube assemblies) with twist and
lock pneumatic connectors on their ends are provided to supply and
return recirculated bath vapors from/to the upper Bath Vessel to/from
the lower Control Chassis. The sex and type of these connectors
constrain their use in only one way - the proper configuration.
3.) One glass jar with lid is provided to catch the bath overflow liquid
and is to be mounted on the rear overflow jar support along with
three pieces of small diameter silicon tubing and an in-line pump
with connector. For instructions on assembling the overflow jar
support and connecting the Reciprocating Pump, see page 7. The
plastic lid for the jar has a hole into which the 3" tubing is inserted.
The other end of the 3" tubing is connected to the bath overflow
outlet. The 6" tube connects the fitting at the bottom of the jar to the
bottom of the air pump, and the top of the air pump is connected to
the 11" tubing which then rises to the top of the Bath Vessel housing
and mates to the bath fluid return pipe.
4.) One Platinum RTD sensor assembly is provided, with the probe and
part of the cable contained under the top plate of the upper Bath
Vessel Housing. This cable has a metal, bayonet style, connector on
one end to be plugged into the back of the lower Control Chassis.
5.) Two hole covers, one 1/4-20 cap nut, and one mercury thermometer
holder are provided.
CANNON
®
TE-3000 Thermoelectric Constant Temperature Bath
Version 1.1c — May, 2005; CANNON
2139 High Tech Road • State College, PA 16803 • USA
®