Program I/O Alarm Messages; Program Output Operating Procedure - mori seiki NZ-S1500 Operation Manual

Table of Contents

Advertisement

A-60
OPERATION PANELS
6-2-2

Program I/O Alarm Messages

In some cases, an alarm message is displayed on attempting to input a program.
In such cases, resolve the problem by referring to the table below.
Cause of the Alarm
Another program is registered with
the same program number.
The number of programs that can
be registered in the NC memory is
set to 0.
Not enough memory area is
available.
Bit 0 of NC parameter No. 0 is set to
"1" (execute TV check).
An attempt has been made to
register a program with an O
number for which program editing is
restricted (O8000 to O9999).
6-2-3

Program Output Operating Procedure

<Outputting to a Memory Card>
1)
Insert a memory card into the card slot.
2)
Set the PANEL key-switch to the
3)
Select the mode selection switch
4)
Display the PROGRAM EDIT screen or PROGRAM DIRECTORY screen.
Press the [(OPRT)] → [+] → [PUNCH] soft-keys.
5)
Function selection key
Register the program with an O number that is not
registered in the NC.
Set bit 2 of NC parameter No. 3201 to "1" so that a
program can be registered using an O number that is
already registered in the NC.
Delete unnecessary programs in the NC memory to
enable registration of the program.
Check the number of programs that can be registered
using the PROGRAM DIRECTORY screen.
Delete unnecessary programs in the NC memory to free
up enough memory area to register the program.
Check the available memory area using the PROGRAM
DIRECTORY screen.
Set bit 0 of NC parameter No. 0 to "0" so that no TV
check is executed.
Register the program by specifying an O number for
which program editing is not restricted.
To enable program editing of O8000 to O8999: Set bit 0
of NC parameter No. 3202 to "0".
To enable program editing of O9000 to O9999: Set bit 4
of NC parameter No. 3202 to "0".
(PANEL/EDIT) position.
(EDIT).
(PROG)
PROG
Remedy