3
Installation and Wiring
This section introduces how CMC-PN01 connects to VFD-C2000 and to network.
3.1 Installation
How to connect CMC-PN01 to VFD-C2000:
Shut off the power supply to the AC motor drive.
Open the front cover of the AC motor drive.
Place the insulation spacer into the positioning pin at Slot 1 (see Figure 1), and
line-up the two holes on the PCB at the positioning pin. Press the pin to clip the
holes on the PCB (see Figure 2).
Ensure the PCB is securely placed, and then fix the screws with 6–8 kg-cm of torque
(5.21–6.94 lb-in.) as shown in Figure 3.
CAUTION
Do not remove
this cover,except
for servicing
警
告
禁止移除上蓋,
維修除外。
CL001
+2
+1
DC-
B1 B2
DC+
制? ? 阻
DC-/DC+
直流共母
?
+2
+1
B1 B2
DC-
DC+
POWER /
電源
M
MOTOR /
3
Figure 1
3.2 Unloading
How to detach CMC-PN01 from VFD-C2000:
Shut off the power supply to the AC motor drive.
Open the front cover of the AC motor drive.
Remove the two screws (see Figure 4).
Pull to open the card clip and put a flat-head screwdriver into the groove to pry the
PCB off the card clip (see Figure 5).
Release the other card clip to remove the PCB (see Figure 6).
Figure 4
CMC-PN01 Operation Manual
VFD-C2000 PROFINET Communication Card CMC-PN01
Figure 2
Figure 5
Figure 3
Figure 6
9