Delta VFD-C2000 Operation Manual page 15

Profinet communication card
Table of Contents

Advertisement

VFD
4
LSB
Fault/Control
2002h
Command
5
MSB
6
LSB
2003h
7
MSB
8
LSB
2004h
9
MSB
10
LSB
2005h
11
MSB
12
LSB
2006h
13
MSB
14
LSB
2007h
15
MSB
16
LSB
2008h
17
MSB
18
LSB
2009h
19
MSB
Table 4: 21xx Input Message (DriveHost Controller) (Pr.09-30=0)
Bytes
Order
Command
0
LSB
Fault
Status
1
MSB
2
LSB
Operation
Status
3
MSB
CMC-PN01 Operation Manual
VFD-C2000 PROFINET Communication Card CMC-PN01
b0
1:EF (external fault) ON
b1
1: Reset
W
b2
1: b.b. ON
b3
1: HAND-ON/LOC-ON command
b4
1: AUTO-ON/REM-ON command
b15–b5
Not used
W
b15–b0
W
b15–b0
W
b15–b0
W
b15–b0
W
b15–b0
W
b15–b0
W
b15–b0
Address
Attribute
b7–b0
Error Code
2100h
R
b15–b8
Warn Code
00: RUN LED light off, STOP LED
light up (Drive Stop)
01: RUN LED blink, STOP LED light
up (Drive Decelerate during the
b1–b10
drive stopping)
10: RUN LED light up, STOP LED
blink (Drive standby)
11: RUN LED light up, STOP LED
light off (Drive Run)
b2
1: JOG active
00: REV LED light off, FWD LED
light up (Forward)
01: REV LED blink, FWD LED light
up (Reverse to Forward)
b4–b3
10: REV LED light up, FWD LED
blink (Forward to Reverse)
11: REV LED light up, FWD LED
light off (Reverse)
b5
1: Factory parameters opened
2101h
R
b6
Reserved
1: Operation command controlled by
b7
external terminal
1: Main Freq. controlled by
b8
communication
1: Main Freq. controlled by external
b9
terminal (AI)
1: Operation command controlled by
b10
Communication
b11
1: Parameters been locked
b12
0: AC drive stop, 1: AC drive run
b13
Jog command
External Fault (EF) enabled
Fault Reset command
External B.B. (Base Block)
enabled
HAND/LOCAL frequency
operation source enabled
AUTO/REMOTE frequency
operation source enabled
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Value
Definition
Fault codes
Warning
codes
Run and stop
status
JOG running
status
Operation
direction
status
Factory
parameter
ON/OFF
status (not
used)
Parameter
Lock ON/OFF
status
VFD actual
running output
status
(RUNNING=1)
JOG running
way of communication.
1. This bit is used for triggering an
external fault to VFD to stop the running
status. The method for stopping can be
set by VFD parameter.
2. This bit operates by on-shot method
and this fault can only be restored by
Fault Reset command.
This bit is used for resetting the status
from Fault to Ready.
This bit is used for triggering an external
B.B. to VFD to pause the running status.
When bit=0 (BB is dismissed), VFD
immediately returns to its former status.
Whether switching HAND/AUTO or
LOC/REM would lead to running STOP
depends on motor drive's parameter
settings.
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Description
Bits in this column are used for checking if VFD
occurs any fault, and using the fault codes to
substitute 32XXh to obtain the description strings for
the fault.
Bits in this column are used for checking if VFD
occurs any warnings, and using the warning codes to
substitute 33XXh to obtain the description strings for
the fault.
Bits in this column are used for checking VFD's
running status in order to control its LED display.
Bits in this column are used for checking VFD's
running direction status in order to control its LED
display.
Bits in this column are used for checking whether
VFD's current operation command source is external
terminal or not. If bit=1, external terminal has the
highest processing priority. Master communication
can obtain control rights only when it switches
operation command source by 2000h b14–13.
Bits in this column are used for checking the current
VFD frequency command source.
Bits in this column are used for checking whether the
current
VFD
operation
command
source
communication or not.
Bits in this column are used for checking whether
VFD's parameters are locked or not. If bit=1, the
values for reading parameters are always 0.
are
15

Advertisement

Table of Contents
loading

Table of Contents