X-Rack Owner's Manual
A.2.3 HF/LF Section
This section contains simple high and low pass filters as follows:
HF (Low Pass):
LF (High Pass):
The two filters can be switched into circuit independently.
A.2.4 OUTPUT Section
This small section contains a tri-colour signal present indicator and two routing
switches ('REC L' and 'REC R') which route the module signal onto a common
internal record bus.
The signal present indicator measures signals immediately prior to the output
amplifier. It will light GREEN for output signals above the lower threshold of
–60dBu, AMBER for signals between +4dBu and +24dBu and lights RED for signals
above +24dBu.
The record bus is not currently used but may be used by forthcoming X-Rack
modules (such as the XR622 Mix/Monitor Module, due late 2006).
Page A-2
3
Frequency range 50kHz – 3kHz (–3dB point)
Slope: 12dB/Octave
Frequency range 30Hz – 600Hz (–3dB point)
Slope: 18dB/Octave
4
XR621
SEL
MIC
INST
IMP
IN
LO
HI
Z
+48V
PAD
+12
+75
dB
LINE
LINE
-20 dB
+20
Ø
HF
9
6
30
4
IN
3
50
3
KHz
LF
160
300
60
IN
30
600
OUTPUT
REC
L
SIGNAL
REC
4
R
INSTRUMENT
GND
LIFT
Need help?
Do you have a question about the 82S6XR0A0B and is the answer not in the manual?