List Of Capacities For 8S50Me-B9.3-Tii At Nmcr - Man B&W S50ME-B9.3-TII Project Manual

Electronically controlled two-stroke engines with camshaft controlled exhaust valves
Table of Contents

Advertisement

MAN B&W

List of Capacities for 8S50ME-B9.3-TII at NMCR

Pumps
Fuel oil circulation
m³/h
Fuel oil supply
m³/h
Jacket cooling
m³/h
Seawater cooling *
m³/h
Main lubrication oil *
m³/h
Central cooling *
m³/h
Scavenge air cooler(s)
Heat diss. app.
kW
Central water flow
m³/h
Seawater flow
m³/h
Lubricating oil cooler
Heat diss. app. *
kW
Lube oil flow *
m³/h
Central water flow
m³/h
Seawater flow
m³/h
Jacket water cooler
Heat diss. app.
kW
Jacket water flow
m³/h
Central water flow
m³/h
Seawater flow
m³/h
Central cooler
Heat diss. app. *
kW
Central water flow
m³/h
Seawater flow
m³/h
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume
Compressor cap.
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume
Compressor cap.
Other values
Fuel oil heater
kW
Exh. gas temp. **
°C
Exh. gas amount **
kg/h
Air consumption **
kg/s
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel & Turbo recommended type and/or torsional
vibration damper the engine's capacities must be increased by those stated for the actual system
** ISO based
For List of Capacities for derated engines and performance data at part load please visit http://www.mandieselturbo/ceas/index.htm
Table 6.03.01h: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR
MAN B&W S50ME-B9.3-TII
Seawater cooling
Conventional TC
6.7
6.7
6.7
3.9
3.9
3.9
129
129
129
432
437
440
280
270
280
-
-
-
5,290
5,290
5,290
-
-
-
259
259
259
1,180
1,220
1,240
275
273
275
-
-
-
173
179
182
2,240
2,240
2,240
135
135
135
-
-
-
173
179
182
-
-
-
-
-
-
-
-
-
2 x 5.0
2 x 5.0
2 x 5.0
300
300
300
2 x 3.0
2 x 3.0
2 x 3.0
180
180
180
112
112
112
255
255
255
102,087 102,087 102,087 107,768 107,768 107,768
27.7
27.7
27.7
High eff. TC
6.7
6.7
6.7
3.8
3.8
3.8
129
129
129
441
446
449
280
270
280
-
-
-
5,470
5,470
5,470
-
-
-
267
267
267
1,180
1,220
1,240
275
273
275
-
-
-
173
179
182
2,240
2,240
2,240
135
135
135
-
-
-
173
179
182
-
-
-
-
-
-
-
-
-
2 x 5.0
2 x 5.0
2 x 5.0
300
300
300
2 x 3.0
2 x 3.0
2 x 3.0
180
180
180
112
112
112
235
235
235
102,087 102,087 102,087 107,768 107,768 107,768
29.3
29.3
29.3
MAN Diesel
Central cooling
Conventional TC
6.7
6.7
6.7
3.9
3.9
3.9
129
129
129
425
427
428
280
270
280
335
339
342
5,270
5,270
5,270
188
188
188
-
-
-
1,180
1,220
1,240
275
273
275
146
150
152
-
-
-
2,250
2,250
2,250
129
129
129
146
150
152
-
-
-
8,700
8,740
8,760
335
339
342
425
427
428
2 x 5.0
2 x 5.0
2 x 5.0
2 x 5.0
300
300
300
2 x 3.0
2 x 3.0
2 x 3.0
2 x 3.0
180
180
180
112
112
112
255
255
255
27.7
27.7
27.7
6.03
Page 4 of 5
High eff. TC
6.7
6.7
6.7
3.8
3.8
3.8
129
129
129
434
436
436
280
270
280
341
346
348
5,440
5,440
5,440
194
194
194
-
-
-
1,180
1,220
1,240
275
273
275
146
150
152
-
-
-
2,250
2,250
2,250
129
129
129
146
150
152
-
-
-
8,870
8,910
8,930
341
346
348
434
436
436
2 x 5.0
2 x 5.0
300
300
300
2 x 3.0
2 x 3.0
180
180
180
112
112
112
235
235
235
29.3
29.3
29.3
198 87 18-1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents