Vaderstad Rapid RDA 400S Original Instructions Manual page 63

Hide thumbs Also See for Rapid RDA 400S:
Table of Contents

Advertisement

3.30.3
Programming
The Control Station has been preset at the Väderstad factory depending on the type and size of the
machine it is supplied with. The Control Station settings need to be reentered after replacement or
a reset.
It is also possible to use the settings to adjust e.g., alarm delays, area metering, etc.
To enter the programming menu, keep
er switch (1).
If the Control Station already has been switched on, switch to the programming menu by keeping
the button
mode, select the last menu in the scroll list:
Use the selection dial to select the desired menu. Selections are shown against a dark background.
Use
to confirm a selection and then select or change the value of the selected item. Confirm
the value/selection with
Menus:
1
Language. Select the desired language for alarm texts, etc.
2
Machine type. Select "RDA 400 S".
3
Hydraulic feeding, Yes/No.
4
GPS, Yes/no. See "3.30.6 GPS (Global Positioning System)" on page 66.
5
Number of pulses per revolution generated by the seed box drive sensor. Default setting:
360.
6
Serial number. Record the serial number of the machine here. Select digits with the dial
and advance using
7
Machine width. Set the machine width here: 4.0 m.
8
Manual start. Select the intended drive speed here by keeping the button
pressed. (Starting of feed output when drilling is commenced from a corner of the field, etc.)
9
Output stop, Yes/No. Option Default setting: No.
menu 9, Setting of lift time delay. Default setting 0.0 sec.
10
Radar, Yes/No.
27.06.2011
ver.2
depressed for 5 seconds. To complete programming and return to the drive
.
.
pressed while simultaneously switching on the pow-
. Confirm with
Only if Yes has been selected in
RDA 400S
.
de-
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rapid rda seriesRapid rda 800s