Vaderstad Rapid RDA 400S Original Instructions Manual page 49

Hide thumbs Also See for Rapid RDA 400S:
Table of Contents

Advertisement

5 To access the calibration menu, depress the
(Alternatively, the calibration menu can be called up by simultaneously depressing the
and
buttons on the Control Station.)
Figure 3.55
! Use the dial to select a row in the menu, mark the row and press
6 Mark the menu row
with
.
7 Mark the menu row
ume as a percentage for the electrically adjustable sown amount. Confirm with
8 Scroll down to the menu row "Calibrate" and depress
Figure 3.56
9 Fill the seed output system by depressing the
tively, the corresponding button on the remote control can be used.
Empty the calibration bag.
27.06.2011
ver.2
with
. Enter the desired output volume in kg/hectare. Confirm
with
. Enter the desired increase/decrease of the output vol-
button on the Control Station.
to confirm.
.
button above the
RDA 400S
.
button. Alterna-
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rapid rda seriesRapid rda 800s

Table of Contents