NEC EGW101 User Manual page 55

Neoface access control
Table of Contents

Advertisement

Chapter 2 Installation and Connection
(3)
Installation Environmental Conditions
Places suitable for the installation of
can be used under the following installation environment conditions.
NeoFace
is recommended to be installed such that there is no reflection on the camera image due to sunlight, sunset, and ceiling
NeoFace
lamps.
Items
Ambient temperature
Storage temperature
Ambient humidity (non-
condensing)
Storage temperature range
Air borne dust
Corrosive gas
Earthquake resistance
Impact resistance (XYZ)
Power supply voltage
Power supply frequency
Power supply noise
Insulation resistance
Insulation withstand voltage
Leak current
Electrostatic yield strength
Momentary power failure
Grounding
Others
*1 Do not use the optional AC adapter outdoors without dust and water proof measures.
When using the AC adapter outdoors, take adequate measures such as placing in a dust proof/waterproof cabinet
avoiding exposure to direct sunlight and rainwater.
*2 The power cord that is connected to the optional AC adapter cannot be plugged into the 200 V AC electric outlet.
Connect to a 100 V AC outlet.
is as follows.
NeoFace
Installation Environmental Conditions
5 to 45℃
-20 to 60℃
20 to 85%
5 to 95%
Should not be too dusty [0.3mg/m
JEITA IT-1004 A class B
Conductive and hygroscopic dust should not be present
IP54 compatible *1
Should be an environment gas is not detected
JEITA IT-1004 A class A
Continuous
2.0m/s
2
Short time 4.9m/s
2
JEITA IT-1004 A classB
2
Electricity ON 19.6 m/s
Electricity OFF 98 m/s
AC100 to 240V ±10%(AC90 to 264V)※2
50 / 60 Hz ± 3Hz
1kVP-P 50ns to 1μs pulse
30MΩ(DC500V)
3.0 kV AC 1 minute
Less than or equal to 1mA
±6 kV (Contact discharge), ±8 kV (Air discharge)
Less than or equal to 30ms (at rated voltage)
Class D
IP54 compatible *1
NeoFace Access Control User's Guide
]